Energy Performance Certificate
17 BONNETHILL PLACE , DUNDEE, DD1 2AD
Energy rating
Current: 76 C | Potential: 82 B
Environmental impact (CO₂)
Current: 65
| Potential: 70
| Field | Value |
|---|---|
| Id | 4095301 |
| BUILDING REFERENCE NUMBER | 1000715383 |
| OSG REFERENCE NUMBER | 9059011918 |
| ADDRESS1 | 17 BONNETHILL PLACE |
| ADDRESS2 | — |
| ADDRESS3 | DUNDEE |
| POSTCODE | DD1 2AD |
| INSPECTION DATE | 2016-06-07 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-13 |
| ENERGY CONSUMPTION CURRENT | 231.00 |
| TOTAL FLOOR AREA | 120 |
| 3 YR ENERGY COST CURRENT | 2613.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 585.0000 |
| CURRENT ENERGY EFFICIENCY | 76 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 82 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 65 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 70 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 39.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £25; Typical Saving: 23; Energy Rating after improvement: C 77; Environmental Rating after improvement: D 67; Green Deal Eligible: N | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £1,600 - £2,400; Typical Saving: 155; Energy Rating after improvement: B 82; Environmental Rating after improvement: C 70; Green Deal Eligible: Y | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 17; Energy Rating after improvement: C 77; Environmental Rating after improvement: D 66; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor | Poor |
| WALL ENV EFF | Poor | Poor |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Manual charge control |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 62% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.70 |
| CO2 EMISSIONS POTENTIAL | 0.60 |
| HEATING COST CURRENT | 1545.0000 |
| HEATING COST POTENTIAL | 1275.0000 |
| HOT WATER COST CURRENT | 720.00 |
| HOT WATER COST POTENTIAL | 501.00 |
| LIGHTING COST CURRENT | 348.00 |
| LIGHTING COST POTENTIAL | 252.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 5903 |
| WATER HEATING DEMAND | 2456 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -1655 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 2.3 |
| DATA ZONE | S01001122 (Docks and Wellgate) |
| ENERGY CONSUMPTION POTENTIAL | 204.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 13 |
| LOW ENERGY FIXED LIGHT COUNT | 8 |
| LOW ENERGY LIGHTING | 62.00 |
| FLOOR LEVEL | mid floor |
| FLAT TOP STOREY | 02 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | no corridor |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Dundee City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric storage heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2401 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QJMD |
| CONSTITUENCY LABEL | Coldside |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Maisonette |
| DATA ZONE 2011 | S01007712 (Docks and Wellgate - 06) |
| CREATED AT | 13/06/2016 11:00:16 |
| REPORT REFERENCE NUMBER | 3700-5133-0529-7008-1663 |
| Source file | Q2 2016.csv |
| Address display | 17 BONNETHILL PLACE , DUNDEE |
| Nation | scotland |