Energy Performance Certificate

57 STRATHCLYDE HOUSE , SHORE ROAD , SKELMORLIE, PA17 5AN

EPC Report

Energy rating

Current: 74 C | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 75 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 Current: 75 76 Potential: 76
Field Value
Id 4128582
BUILDING REFERENCE NUMBER 1000657363
OSG REFERENCE NUMBER 126064499
ADDRESS1 57 STRATHCLYDE HOUSE
ADDRESS2 SHORE ROAD
ADDRESS3 SKELMORLIE
POSTCODE PA17 5AN
INSPECTION DATE 2016-06-22
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2017-06-22
ENERGY CONSUMPTION CURRENT 248.00
TOTAL FLOOR AREA 44
3 YR ENERGY COST CURRENT 1392.0000
3 YR ENERGY SAVINGS POTENTIAL 24.0000
CURRENT ENERGY EFFICIENCY 74
CURRENT ENERGY RATING C
POTENTIAL ENERGY EFFICIENCY 75
POTENTIAL ENERGY RATING C
ENVIRONMENT IMPACT CURRENT 75
CURRENT ENVIRONMENTAL RATING C
ENVIRONMENT IMPACT POTENTIAL 76
POTENTIAL ENVIRONMENTAL RATING C
CO2 EMISS CURR PER FLOOR AREA 44.00
IMPROVEMENTS Description: Low energy lighting for all fixed outlets; Indicative Cost: £10; Typical Saving: 8; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 76; Green Deal Eligible: N |
WALL DESCRIPTION Cavity wall, as built, insulated (assumed)
WALL ENERGY EFF Good
WALL ENV EFF Good
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Flat rate charging, programmer and TRVs
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 1.90
CO2 EMISSIONS POTENTIAL 0.00
HEATING COST CURRENT 936.0000
HEATING COST POTENTIAL 942.0000
HOT WATER COST CURRENT 321.00
HOT WATER COST POTENTIAL 321.00
LIGHTING COST CURRENT 135.00
LIGHTING COST POTENTIAL 105.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 3721
WATER HEATING DEMAND 1810
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1999-2002
FLOOR HEIGHT 3
DATA ZONE S01004525 (Skelmorlie and Rural)
ENERGY CONSUMPTION POTENTIAL 245.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
LOW ENERGY LIGHTING 71.00
FLOOR LEVEL top floor
FLAT TOP STOREY 02
GLAZED AREA 1
NUMBER HABITABLE ROOMS 2
HEAT LOSS CORRIDOOR heated corridor
NUMBER HEATED ROOMS 2
LOCAL AUTHORITY LABEL North Ayrshire
MAINS GAS FLAG
MAIN HEATING CATEGORY community heating system
MAIN FUEL mains gas (community)
MAIN HEATING CONTROLS 2305
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QYMH
CONSTITUENCY LABEL North Coast and Cumbraes
WIND TURBINE COUNT 0
BUILT FORM Enclosed Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01011335 (Skelmorlie and Rural - 02)
CREATED AT 22/06/2017 21:38:23
REPORT REFERENCE NUMBER 3600-7523-0729-1026-1663
Source file Q2 2017.csv
Address display 57 STRATHCLYDE HOUSE , SHORE ROAD , SKELMORLIE
Nation scotland