Energy Performance Certificate
64 KILBIRNIE TERRACE , DENNY, FK6 6JL
Energy rating
Current: 59 D | Potential: 85 B
Environmental impact (CO₂)
Current: 45
| Potential: 68
| Field | Value |
|---|---|
| Id | 4095387 |
| BUILDING REFERENCE NUMBER | 1000683663 |
| OSG REFERENCE NUMBER | 136068580 |
| ADDRESS1 | 64 KILBIRNIE TERRACE |
| ADDRESS2 | — |
| ADDRESS3 | DENNY |
| POSTCODE | FK6 6JL |
| INSPECTION DATE | 2016-06-18 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-19 |
| ENERGY CONSUMPTION CURRENT | 382.00 |
| TOTAL FLOOR AREA | 97 |
| 3 YR ENERGY COST CURRENT | 3651.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1452.0000 |
| CURRENT ENERGY EFFICIENCY | 59 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 85 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 45 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 68 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 65.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £40; Typical Saving: 43; Energy Rating after improvement: D 64; Environmental Rating after improvement: E 50; Green Deal Eligible: N | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 53; Energy Rating after improvement: C 75; Environmental Rating after improvement: D 60; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 261; Energy Rating after improvement: B 85; Environmental Rating after improvement: D 68; Green Deal Eligible: Y | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £2,000 - £3,000; Typical Saving: 280; Energy Rating after improvement: C 74; Environmental Rating after improvement: D 55; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 86; Energy Rating after improvement: D 62; Environmental Rating after improvement: E 48; Green Deal Eligible: Y | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 22; Energy Rating after improvement: D 62; Environmental Rating after improvement: E 49; Green Deal Eligible: Y | |
| WALL DESCRIPTION | System built, with external insulation |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 200 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Manual charge control |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Portable electric heaters (assumed) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 11% of fixed outlets |
| LIGHTING ENERGY EFF | Poor |
| LIGHTING ENV EFF | Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 6.20 |
| CO2 EMISSIONS POTENTIAL | 2.60 |
| HEATING COST CURRENT | 2355.0000 |
| HEATING COST POTENTIAL | 1686.0000 |
| HOT WATER COST CURRENT | 912.00 |
| HOT WATER COST POTENTIAL | 309.00 |
| LIGHTING COST CURRENT | 384.00 |
| LIGHTING COST POTENTIAL | 204.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 9059 |
| WATER HEATING DEMAND | 2225 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1965-1975 |
| FLOOR HEIGHT | 2.45 |
| DATA ZONE | S01002545 (Fankerton, Stoneywood and Denny Town) |
| ENERGY CONSUMPTION POTENTIAL | 218.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 9 |
| LOW ENERGY FIXED LIGHT COUNT | 1 |
| LOW ENERGY LIGHTING | 11.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 5 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 5 |
| LOCAL AUTHORITY LABEL | Falkirk |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric storage heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2401 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | ECO assessment |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QQMC |
| CONSTITUENCY LABEL | Denny and Banknock |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01009058 (Fankerton, Stoneywood and Denny Town - 04) |
| CREATED AT | 19/06/2016 20:43:32 |
| REPORT REFERENCE NUMBER | 3600-3886-0329-4096-1663 |
| Source file | Q2 2016.csv |
| Address display | 64 KILBIRNIE TERRACE , DENNY |
| Nation | scotland |