Energy rating

Current: 88 B | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 B Current: 88 B 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 89 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 89 Current: 89 89 Potential: 89
Field Value
Id 4036057
BUILDING REFERENCE NUMBER 1236519623
OSG REFERENCE NUMBER
ADDRESS1 Flat 1
ADDRESS2 38 Henderson Place
ADDRESS3 Edinburgh
POSTCODE EH3 5DJ
INSPECTION DATE 2025-01-07
TYPE OF ASSESSMENT SAP, new dwelling
LODGEMENT DATE 2025-01-07
ENERGY CONSUMPTION CURRENT 87.00
TOTAL FLOOR AREA 65
3 YR ENERGY COST CURRENT 1389.0000
3 YR ENERGY SAVINGS POTENTIAL 0.0000
CURRENT ENERGY EFFICIENCY 88
CURRENT ENERGY RATING B
POTENTIAL ENERGY EFFICIENCY 88
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 89
CURRENT ENVIRONMENTAL RATING B
ENVIRONMENT IMPACT POTENTIAL 89
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 15.00
IMPROVEMENTS
WALL DESCRIPTION Average thermal transmittance 0.20 W/m²K
WALL ENERGY EFF Very Good
WALL ENV EFF Very Good
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION Average thermal transmittance 0.13 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION Description: High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION Air permeability 5.0 m³/h.m² (assumed)
AIR TIGHTNESS ENERGY EFF Good
AIR TIGHTNESS ENV EFF Good
CO2 EMISSIONS CURRENT 1.00
CO2 EMISSIONS POTENTIAL 0.00
HEATING COST CURRENT 645.0000
HEATING COST POTENTIAL 645.0000
HOT WATER COST CURRENT 510.00
HOT WATER COST POTENTIAL 510.00
LIGHTING COST CURRENT 234.00
LIGHTING COST POTENTIAL 234.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES Description: Air source heat pump |
SPACE HEATING DEMAND 1679
WATER HEATING DEMAND 1856
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND
FLOOR HEIGHT 2.4
DATA ZONE S01002201 (New Town West)
ENERGY CONSUMPTION POTENTIAL 87.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 18
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL ground floor
FLAT TOP STOREY
GLAZED AREA 0
NUMBER HABITABLE ROOMS 0
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 0
LOCAL AUTHORITY LABEL Edinburgh City
MAINS GAS FLAG
MAIN HEATING CATEGORY heat pump with radiators or underfloor heating
MAIN FUEL Electricity: electricity, unspecified tariff
MAIN HEATING CONTROLS 2207
MECHANICAL VENTILATION
ENERGY TARIFF
MULTI GLAZE PROPORTION 0
GLAZED TYPE
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
TENURE unknown
TRANSACTION TYPE new dwelling
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QPME
CONSTITUENCY LABEL Inverleith
WIND TURBINE COUNT 0
BUILT FORM Semi-Detached
PROPERTY TYPE Flat
DATA ZONE 2011 S01008855 (Canonmills and New Town North - 03)
CREATED AT 07/01/2025 12:43:10
REPORT REFERENCE NUMBER 3115-2139-6630-2913-5206
Source file Q1 2025.csv
Address display Flat 1 , 38 Henderson Place , Edinburgh