Energy Performance Certificate
Flat Ground-1 , 70 Regent Street , Greenock, PA15 4RH
Energy rating
Current: 46 E | Potential: 78 C
Environmental impact (CO₂)
Current: 30
| Potential: 62
| Field | Value |
|---|---|
| Id | 4110163 |
| BUILDING REFERENCE NUMBER | 1002137833 |
| OSG REFERENCE NUMBER | 119016463 |
| ADDRESS1 | Flat Ground-1 |
| ADDRESS2 | 70 Regent Street |
| ADDRESS3 | Greenock |
| POSTCODE | PA15 4RH |
| INSPECTION DATE | 2016-06-27 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-27 |
| ENERGY CONSUMPTION CURRENT | 655.00 |
| TOTAL FLOOR AREA | 61 |
| 3 YR ENERGY COST CURRENT | 3642.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 2136.0000 |
| CURRENT ENERGY EFFICIENCY | 46 |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY EFFICIENCY | 78 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 30 |
| CURRENT ENVIRONMENTAL RATING | F |
| ENVIRONMENT IMPACT POTENTIAL | 62 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 111.00 |
| IMPROVEMENTS | Description: Insulate hot water cylinder with 80 mm jacket; Indicative Cost: £15 - £30; Typical Saving: 235; Energy Rating after improvement: C 70; Environmental Rating after improvement: D 56; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 63; Energy Rating after improvement: E 53; Environmental Rating after improvement: F 37; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 136; Energy Rating after improvement: D 59; Environmental Rating after improvement: E 43; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 105; Energy Rating after improvement: E 50; Environmental Rating after improvement: F 34; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £30; Typical Saving: 35; Energy Rating after improvement: C 72; Environmental Rating after improvement: D 57; Green Deal Eligible: N | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £1,200 - £1,800; Typical Saving: 138; Energy Rating after improvement: C 78; Environmental Rating after improvement: D 62; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor | Poor |
| WALL ENV EFF | Poor | Poor |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Manual charge control |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Very Poor |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 6.80 |
| CO2 EMISSIONS POTENTIAL | 3.70 |
| HEATING COST CURRENT | 1713.0000 |
| HEATING COST POTENTIAL | 945.0000 |
| HOT WATER COST CURRENT | 1638.00 |
| HOT WATER COST POTENTIAL | 417.00 |
| LIGHTING COST CURRENT | 291.00 |
| LIGHTING COST POTENTIAL | 144.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 6559 |
| WATER HEATING DEMAND | 5894 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | -1232 |
| IMPACT SOLID WALL INSULATION | -732 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | 2.4 |
| DATA ZONE | S01004086 (Greenock Town Centre and East Central) |
| ENERGY CONSUMPTION POTENTIAL | 304.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | ground floor |
| FLAT TOP STOREY | 00 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Inverclyde |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric storage heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2401 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | 6.11 |
| CONSTITUENCY | 00QUMC |
| CONSTITUENCY LABEL | Inverclyde North |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01010890 (Greenock Town Centre and East Central - 01) |
| CREATED AT | 27/06/2016 16:24:15 |
| REPORT REFERENCE NUMBER | 3100-6338-0729-4223-1663 |
| Source file | Q2 2016.csv |
| Address display | Flat Ground-1 , 70 Regent Street , Greenock |
| Nation | scotland |