Energy Performance Certificate

Flat Ground-1 , 70 Regent Street , Greenock, PA15 4RH

EPC Report

Energy rating

Current: 46 E | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 30 | Potential: 62
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 Current: 30 62 Potential: 62
Field Value
Id 4110163
BUILDING REFERENCE NUMBER 1002137833
OSG REFERENCE NUMBER 119016463
ADDRESS1 Flat Ground-1
ADDRESS2 70 Regent Street
ADDRESS3 Greenock
POSTCODE PA15 4RH
INSPECTION DATE 2016-06-27
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2016-06-27
ENERGY CONSUMPTION CURRENT 655.00
TOTAL FLOOR AREA 61
3 YR ENERGY COST CURRENT 3642.0000
3 YR ENERGY SAVINGS POTENTIAL 2136.0000
CURRENT ENERGY EFFICIENCY 46
CURRENT ENERGY RATING E
POTENTIAL ENERGY EFFICIENCY 78
POTENTIAL ENERGY RATING C
ENVIRONMENT IMPACT CURRENT 30
CURRENT ENVIRONMENTAL RATING F
ENVIRONMENT IMPACT POTENTIAL 62
POTENTIAL ENVIRONMENTAL RATING D
CO2 EMISS CURR PER FLOOR AREA 111.00
IMPROVEMENTS Description: Insulate hot water cylinder with 80 mm jacket; Indicative Cost: £15 - £30; Typical Saving: 235; Energy Rating after improvement: C 70; Environmental Rating after improvement: D 56; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 63; Energy Rating after improvement: E 53; Environmental Rating after improvement: F 37; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 136; Energy Rating after improvement: D 59; Environmental Rating after improvement: E 43; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 105; Energy Rating after improvement: E 50; Environmental Rating after improvement: F 34; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £30; Typical Saving: 35; Energy Rating after improvement: C 72; Environmental Rating after improvement: D 57; Green Deal Eligible: N | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £1,200 - £1,800; Typical Saving: 138; Energy Rating after improvement: C 78; Environmental Rating after improvement: D 62; Green Deal Eligible: Y |
WALL DESCRIPTION Cavity wall, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed)
WALL ENERGY EFF Poor | Poor
WALL ENV EFF Poor | Poor
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 6.80
CO2 EMISSIONS POTENTIAL 3.70
HEATING COST CURRENT 1713.0000
HEATING COST POTENTIAL 945.0000
HOT WATER COST CURRENT 1638.00
HOT WATER COST POTENTIAL 417.00
LIGHTING COST CURRENT 291.00
LIGHTING COST POTENTIAL 144.00
ALTERNATIVE IMPROVEMENTS Description: External insulation with cavity wall insulation | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 6559
WATER HEATING DEMAND 5894
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION -1232
IMPACT SOLID WALL INSULATION -732
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1950-1964
FLOOR HEIGHT 2.4
DATA ZONE S01004086 (Greenock Town Centre and East Central)
ENERGY CONSUMPTION POTENTIAL 304.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 0
LOW ENERGY LIGHTING 0.00
FLOOR LEVEL ground floor
FLAT TOP STOREY 00
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL Inverclyde
MAINS GAS FLAG
MAIN HEATING CATEGORY electric storage heaters
MAIN FUEL electricity (not community)
MAIN HEATING CONTROLS 2401
MECHANICAL VENTILATION natural
ENERGY TARIFF dual
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH 6.11
CONSTITUENCY 00QUMC
CONSTITUENCY LABEL Inverclyde North
WIND TURBINE COUNT 0
BUILT FORM Semi-Detached
PROPERTY TYPE Flat
DATA ZONE 2011 S01010890 (Greenock Town Centre and East Central - 01)
CREATED AT 27/06/2016 16:24:15
REPORT REFERENCE NUMBER 3100-6338-0729-4223-1663
Source file Q2 2016.csv
Address display Flat Ground-1 , 70 Regent Street , Greenock
Nation scotland