Energy Performance Certificate
1/2 , 53 BYRON STREET , DUNDEE, DD3 6QU
Energy rating
Current: 76 C | Potential: 79 C
Environmental impact (CO₂)
Current: 80
| Potential: 83
| Field | Value |
|---|---|
| Id | 4103255 |
| BUILDING REFERENCE NUMBER | 1001394573 |
| OSG REFERENCE NUMBER | 9059057950 |
| ADDRESS1 | 1/2 |
| ADDRESS2 | 53 BYRON STREET |
| ADDRESS3 | DUNDEE |
| POSTCODE | DD3 6QU |
| INSPECTION DATE | 2016-04-26 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-04-26 |
| ENERGY CONSUMPTION CURRENT | 182.00 |
| TOTAL FLOOR AREA | 53 |
| 3 YR ENERGY COST CURRENT | 1398.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 198.0000 |
| CURRENT ENERGY EFFICIENCY | 76 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 79 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 80 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 83 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 32.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £30; Typical Saving: 32; Energy Rating after improvement: C 79; Environmental Rating after improvement: B 83; Green Deal Eligible: N | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 33; Energy Rating after improvement: C 78; Environmental Rating after improvement: B 81; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, with external insulation | Solid brick, as built, partial insulation (assumed) |
| WALL ENERGY EFF | Very Good | Average |
| WALL ENV EFF | Very Good | Average |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 1.70 |
| CO2 EMISSIONS POTENTIAL | 0.30 |
| HEATING COST CURRENT | 885.0000 |
| HEATING COST POTENTIAL | 801.0000 |
| HOT WATER COST CURRENT | 285.00 |
| HOT WATER COST POTENTIAL | 285.00 |
| LIGHTING COST CURRENT | 228.00 |
| LIGHTING COST POTENTIAL | 114.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 3324 |
| WATER HEATING DEMAND | 1984 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -641 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1919-1929 |
| FLOOR HEIGHT | 2.6 |
| DATA ZONE | S01001177 (Law) |
| ENERGY CONSUMPTION POTENTIAL | 153.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | mid floor |
| FLAT TOP STOREY | 01 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | Dundee City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | ECO assessment |
| UNHEATED CORRIDOR LENGTH | 5.85 |
| CONSTITUENCY | 00QJMD |
| CONSTITUENCY LABEL | Coldside |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01007831 (Law - 04) |
| CREATED AT | 26/04/2016 09:41:41 |
| REPORT REFERENCE NUMBER | 2863-1013-7204-5446-9904 |
| Source file | Q2 2016.csv |
| Address display | 1/2 , 53 BYRON STREET , DUNDEE |
| Nation | scotland |