Energy Performance Certificate
91 SCALLOWAY PARK , FRASERBURGH, AB43 9FB
Energy rating
Current: 62 D | Potential: 85 B
Environmental impact (CO₂)
Current: 55
| Potential: 82
| Field | Value |
|---|---|
| Id | 4097979 |
| BUILDING REFERENCE NUMBER | 1000866592 |
| OSG REFERENCE NUMBER | 151013776 |
| ADDRESS1 | 91 SCALLOWAY PARK |
| ADDRESS2 | — |
| ADDRESS3 | FRASERBURGH |
| POSTCODE | AB43 9FB |
| INSPECTION DATE | 2016-06-28 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-29 |
| ENERGY CONSUMPTION CURRENT | 309.00 |
| TOTAL FLOOR AREA | 102 |
| 3 YR ENERGY COST CURRENT | 3777.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1365.0000 |
| CURRENT ENERGY EFFICIENCY | 62 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 85 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 55 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 82 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 55.00 |
| IMPROVEMENTS | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 259; Energy Rating after improvement: B 85; Environmental Rating after improvement: B 82; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 77; Energy Rating after improvement: C 70; Environmental Rating after improvement: D 67; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £50; Typical Saving: 52; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 69; Green Deal Eligible: N | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 36; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 74; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 206; Energy Rating after improvement: D 68; Environmental Rating after improvement: D 64; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 83; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor |
| WALL ENV EFF | Poor |
| ROOF DESCRIPTION | Pitched, 100 mm loft insulation |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 5.60 |
| CO2 EMISSIONS POTENTIAL | 3.10 |
| HEATING COST CURRENT | 3012.0000 |
| HEATING COST POTENTIAL | 1992.0000 |
| HOT WATER COST CURRENT | 384.00 |
| HOT WATER COST POTENTIAL | 231.00 |
| LIGHTING COST CURRENT | 381.00 |
| LIGHTING COST POTENTIAL | 189.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Micro CHP | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 16321 |
| WATER HEATING DEMAND | 2245 |
| IMPACT LOFT INSULATION | -571 |
| IMPACT CAVITY WALL INSULATION | -3860 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1965-1975 |
| FLOOR HEIGHT | 2.38 |
| DATA ZONE | S01000560 (Fraserburgh Lochpots) |
| ENERGY CONSUMPTION POTENTIAL | 137.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 10 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Aberdeenshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | none of the above |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QBMC |
| CONSTITUENCY LABEL | Fraserburgh and District |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | End-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01007120 (Fraserburgh Lochpots - 03) |
| CREATED AT | 29/06/2016 08:37:34 |
| REPORT REFERENCE NUMBER | 2800-1685-0629-2029-1663 |
| Source file | Q2 2016.csv |
| Address display | 91 SCALLOWAY PARK , FRASERBURGH |
| Nation | scotland |