Energy Performance Certificate
1 Stewart Court , West Calder, EH55 8EZ
Energy rating
Current: 72 C | Potential: 77 C
Environmental impact (CO₂)
Current: 69
| Potential: 76
| Field | Value |
|---|---|
| Id | 4106092 |
| BUILDING REFERENCE NUMBER | 1001634172 |
| OSG REFERENCE NUMBER | 200004089885 |
| ADDRESS1 | 1 Stewart Court |
| ADDRESS2 | — |
| ADDRESS3 | West Calder |
| POSTCODE | EH55 8EZ |
| INSPECTION DATE | 2016-06-29 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-29 |
| ENERGY CONSUMPTION CURRENT | 227.00 |
| TOTAL FLOOR AREA | 86 |
| 3 YR ENERGY COST CURRENT | 2454.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 510.0000 |
| CURRENT ENERGY EFFICIENCY | 72 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 77 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 69 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 76 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 41.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £50; Typical Saving: 38; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 76; Green Deal Eligible: N | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 133; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 75; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, filled cavity |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Community scheme |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Flat rate charging, TRVs |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Community scheme |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 23% of fixed outlets |
| LIGHTING ENERGY EFF | Poor |
| LIGHTING ENV EFF | Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 3.50 |
| CO2 EMISSIONS POTENTIAL | 0.80 |
| HEATING COST CURRENT | 1737.0000 |
| HEATING COST POTENTIAL | 1365.0000 |
| HOT WATER COST CURRENT | 399.00 |
| HOT WATER COST POTENTIAL | 399.00 |
| LIGHTING COST CURRENT | 318.00 |
| LIGHTING COST POTENTIAL | 180.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | Description: Community combined heat and power | |
| SPACE HEATING DEMAND | 8891 |
| WATER HEATING DEMAND | 2432 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1976-1983 |
| FLOOR HEIGHT | 2.3 |
| DATA ZONE | S01006307 (West Calder) |
| ENERGY CONSUMPTION POTENTIAL | 176.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 13 |
| LOW ENERGY FIXED LIGHT COUNT | 3 |
| LOW ENERGY LIGHTING | 23.00 |
| FLOOR LEVEL | ground floor |
| FLAT TOP STOREY | 00 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | heated corridor |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | West Lothian |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | community heating system |
| MAIN FUEL | mains gas (community) |
| MAIN HEATING CONTROLS | 2307 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | ECO assessment |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00RHMF |
| CONSTITUENCY LABEL | Fauldhouse and the Breich Valley |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | End-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01013257 (West Calder and Polbeth - 02) |
| CREATED AT | 29/06/2016 14:50:24 |
| REPORT REFERENCE NUMBER | 2600-2311-0429-6127-1663 |
| Source file | Q2 2016.csv |
| Address display | 1 Stewart Court , West Calder |
| Nation | scotland |