Energy Performance Certificate

3F2 , 21 STEWART TERRACE , EDINBURGH, EH11 1UP

EPC Report

Energy rating

Current: 61 D | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 57 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 72 Potential: 72
Field Value
Id 3867895
BUILDING REFERENCE NUMBER 1000778523
OSG REFERENCE NUMBER 906282119
ADDRESS1 3F2
ADDRESS2 21 STEWART TERRACE
ADDRESS3 EDINBURGH
POSTCODE EH11 1UP
INSPECTION DATE 2022-03-28
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2022-03-30
ENERGY CONSUMPTION CURRENT 419.00
TOTAL FLOOR AREA 39
3 YR ENERGY COST CURRENT 2475.0000
3 YR ENERGY SAVINGS POTENTIAL 1341.0000
CURRENT ENERGY EFFICIENCY 61
CURRENT ENERGY RATING D
POTENTIAL ENERGY EFFICIENCY 83
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 57
CURRENT ENVIRONMENTAL RATING D
ENVIRONMENT IMPACT POTENTIAL 72
POTENTIAL ENVIRONMENTAL RATING C
CO2 EMISS CURR PER FLOOR AREA 71.00
IMPROVEMENTS Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 241; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 69; Green Deal Eligible: Y | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £800 - £1,200; Typical Saving: 154; Energy Rating after improvement: B 81; Environmental Rating after improvement: D 68; Green Deal Eligible: Y | Description: Replacement glazing units; Indicative Cost: £1,000 - £1,400; Typical Saving: 51; Energy Rating after improvement: B 83; Environmental Rating after improvement: C 72; Green Deal Eligible: Y |
WALL DESCRIPTION Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed)
WALL ENERGY EFF Very Poor | Poor
WALL ENV EFF Very Poor | Poor
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 2.80
CO2 EMISSIONS POTENTIAL 0.90
HEATING COST CURRENT 1785.0000
HEATING COST POTENTIAL 537.0000
HOT WATER COST CURRENT 585.00
HOT WATER COST POTENTIAL 477.00
LIGHTING COST CURRENT 105.00
LIGHTING COST POTENTIAL 120.00
ALTERNATIVE IMPROVEMENTS Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 3701
WATER HEATING DEMAND 1490
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION -1501
ADDENDUM TEXT
CONSTRUCTION AGE BAND before 1919
FLOOR HEIGHT 2.8
DATA ZONE S01002007 (Gorgie West)
ENERGY CONSUMPTION POTENTIAL 280.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 12
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL top floor
FLAT TOP STOREY 03
GLAZED AREA 1
NUMBER HABITABLE ROOMS 2
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 2
LOCAL AUTHORITY LABEL Edinburgh City
MAINS GAS FLAG
MAIN HEATING CATEGORY room heaters
MAIN FUEL electricity (not community)
MAIN HEATING CONTROLS 2602
MECHANICAL VENTILATION natural
ENERGY TARIFF dual
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH 4.97
CONSTITUENCY 00QPMG
CONSTITUENCY LABEL Sighthill/Gorgie
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01008496 (Gorgie West - 05)
CREATED AT 30/03/2022 15:00:36
REPORT REFERENCE NUMBER 2583-1007-2207-5682-7204
Source file Q1 2022.csv
Address display 3F2 , 21 STEWART TERRACE , EDINBURGH