Energy Performance Certificate

79 BLACKTHORN GROVE , MENSTRIE, FK11 7DX

EPC Report

Energy rating

Current: 76 C | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 75 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 Current: 75 87 Potential: 87
Field Value
Id 3860781
BUILDING REFERENCE NUMBER 1000250255
OSG REFERENCE NUMBER 35024969
ADDRESS1 79 BLACKTHORN GROVE
ADDRESS2
ADDRESS3 MENSTRIE
POSTCODE FK11 7DX
INSPECTION DATE 2022-03-22
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2022-03-22
ENERGY CONSUMPTION CURRENT 186.00
TOTAL FLOOR AREA 78
3 YR ENERGY COST CURRENT 1743.0000
3 YR ENERGY SAVINGS POTENTIAL 69.0000
CURRENT ENERGY EFFICIENCY 76
CURRENT ENERGY RATING C
POTENTIAL ENERGY EFFICIENCY 88
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 75
CURRENT ENVIRONMENTAL RATING C
ENVIRONMENT IMPACT POTENTIAL 87
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 33.00
IMPROVEMENTS Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 23; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 77; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 304; Energy Rating after improvement: B 88; Environmental Rating after improvement: B 87; Green Deal Eligible: Y |
WALL DESCRIPTION Timber frame, as built, insulated (assumed)
WALL ENERGY EFF Good
WALL ENV EFF Good
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 2.60
CO2 EMISSIONS POTENTIAL 1.00
HEATING COST CURRENT 1254.0000
HEATING COST POTENTIAL 1254.0000
HOT WATER COST CURRENT 276.00
HOT WATER COST POTENTIAL 207.00
LIGHTING COST CURRENT 213.00
LIGHTING COST POTENTIAL 213.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 7205
WATER HEATING DEMAND 2242
IMPACT LOFT INSULATION -319
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 2003-2007
FLOOR HEIGHT 2.4
DATA ZONE S01000875 (Menstrie)
ENERGY CONSUMPTION POTENTIAL 112.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 11
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 1
NUMBER HABITABLE ROOMS 4
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 4
LOCAL AUTHORITY LABEL Clackmannanshire
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QFMA
CONSTITUENCY LABEL Clackmannanshire West
WIND TURBINE COUNT 0
BUILT FORM Semi-Detached
PROPERTY TYPE House
DATA ZONE 2011 S01007423 (Menstrie - 03)
CREATED AT 22/03/2022 18:31:07
REPORT REFERENCE NUMBER 2425-1002-5207-2802-5200
Source file Q1 2022.csv
Address display 79 BLACKTHORN GROVE , MENSTRIE
Nation scotland