Energy Performance Certificate

183E LOCHEE ROAD , DUNDEE, DD2 2ND

EPC Report

Energy rating

Current: 70 C | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 55 | Potential: 62
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 62 Potential: 62
Field Value
Id 4325981
BUILDING REFERENCE NUMBER 1000702976
OSG REFERENCE NUMBER 9059016164
ADDRESS1 183E LOCHEE ROAD
ADDRESS2
ADDRESS3 DUNDEE
POSTCODE DD2 2ND
INSPECTION DATE 2023-06-21
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2023-06-21
ENERGY CONSUMPTION CURRENT 412.00
TOTAL FLOOR AREA 51
3 YR ENERGY COST CURRENT 5274.0000
3 YR ENERGY SAVINGS POTENTIAL 819.0000
CURRENT ENERGY EFFICIENCY 70
CURRENT ENERGY RATING C
POTENTIAL ENERGY EFFICIENCY 74
POTENTIAL ENERGY RATING C
ENVIRONMENT IMPACT CURRENT 55
CURRENT ENVIRONMENTAL RATING D
ENVIRONMENT IMPACT POTENTIAL 62
POTENTIAL ENVIRONMENTAL RATING D
CO2 EMISS CURR PER FLOOR AREA 70.00
IMPROVEMENTS Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 32; Energy Rating after improvement: C 72; Environmental Rating after improvement: D 59; Green Deal Eligible: Y | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £1,200 - £1,800; Typical Saving: 122; Energy Rating after improvement: C 74; Environmental Rating after improvement: D 62; Green Deal Eligible: Y | Description: Increase loft insulation to 270 mm; Indicative Cost: £100 - £350; Typical Saving: 119; Energy Rating after improvement: C 72; Environmental Rating after improvement: D 58; Green Deal Eligible: Y |
WALL DESCRIPTION Cavity wall, as built, insulated (assumed) | Solid brick, as built, insulated (assumed)
WALL ENERGY EFF Good | Good
WALL ENV EFF Good | Good
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 3.50
CO2 EMISSIONS POTENTIAL 0.50
HEATING COST CURRENT 3612.0000
HEATING COST POTENTIAL 2805.0000
HOT WATER COST CURRENT 1383.00
HOT WATER COST POTENTIAL 1371.00
LIGHTING COST CURRENT 279.00
LIGHTING COST POTENTIAL 279.00
ALTERNATIVE IMPROVEMENTS Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 4738
WATER HEATING DEMAND 1835
IMPACT LOFT INSULATION -474
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1984-1991
FLOOR HEIGHT 2.39
DATA ZONE S01001123 (Logie and Blackness)
ENERGY CONSUMPTION POTENTIAL 347.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL top floor
FLAT TOP STOREY 02
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 1
LOCAL AUTHORITY LABEL Dundee City
MAINS GAS FLAG
MAIN HEATING CATEGORY electric storage heaters
MAIN FUEL electricity (not community)
MAIN HEATING CONTROLS 2401
MECHANICAL VENTILATION natural
ENERGY TARIFF dual (24 hour)
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH 2.95
CONSTITUENCY 00QJMD
CONSTITUENCY LABEL Coldside
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01007700 (Logie and Blackness - 06)
CREATED AT 21/06/2023 14:04:29
REPORT REFERENCE NUMBER 2396-1007-7206-9727-0200
Source file Q2 2023.csv
Address display 183E LOCHEE ROAD , DUNDEE
Nation scotland