Energy Performance Certificate
3F2 , 38 COMELY BANK STREET , EDINBURGH, EH4 1BB
Energy rating
Current: 52 E | Potential: 58 D
Environmental impact (CO₂)
Current: 45
| Potential: 51
| Field | Value |
|---|---|
| Id | 4091606 |
| BUILDING REFERENCE NUMBER | 1000321462 |
| OSG REFERENCE NUMBER | 906322720 |
| ADDRESS1 | 3F2 |
| ADDRESS2 | 38 COMELY BANK STREET |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH4 1BB |
| INSPECTION DATE | 2016-06-21 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-22 |
| ENERGY CONSUMPTION CURRENT | 426.00 |
| TOTAL FLOOR AREA | 63 |
| 3 YR ENERGY COST CURRENT | 3183.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 378.0000 |
| CURRENT ENERGY EFFICIENCY | 52 |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY EFFICIENCY | 58 |
| POTENTIAL ENERGY RATING | D |
| ENVIRONMENT IMPACT CURRENT | 45 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 51 |
| POTENTIAL ENVIRONMENTAL RATING | E |
| CO2 EMISS CURR PER FLOOR AREA | 75.00 |
| IMPROVEMENTS | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 34; Energy Rating after improvement: D 58; Environmental Rating after improvement: E 51; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 91; Energy Rating after improvement: D 56; Environmental Rating after improvement: E 50; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor |
| WALL ENV EFF | Poor |
| ROOF DESCRIPTION | Pitched, no insulation (assumed) |
| ROOF ENERGY EFF | Very Poor |
| ROOF ENV EFF | Very Poor |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.70 |
| CO2 EMISSIONS POTENTIAL | 0.60 |
| HEATING COST CURRENT | 2742.0000 |
| HEATING COST POTENTIAL | 2364.0000 |
| HOT WATER COST CURRENT | 306.00 |
| HOT WATER COST POTENTIAL | 306.00 |
| LIGHTING COST CURRENT | 135.00 |
| LIGHTING COST POTENTIAL | 135.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 11126 |
| WATER HEATING DEMAND | 1898 |
| IMPACT LOFT INSULATION | -6137 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -1522 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 3.1 |
| DATA ZONE | S01002177 (Comely Bank) |
| ENERGY CONSUMPTION POTENTIAL | 370.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 6 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 03 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 1 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (private) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | 2.25 |
| CONSTITUENCY | 00QPME |
| CONSTITUENCY LABEL | Inverleith |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01008866 (Comely Bank - 03) |
| CREATED AT | 22/06/2016 07:22:56 |
| REPORT REFERENCE NUMBER | 2300-7294-0129-6026-1663 |
| Source file | Q2 2016.csv |
| Address display | 3F2 , 38 COMELY BANK STREET , EDINBURGH |
| Nation | scotland |