Energy Performance Certificate
36H FOREST PARK PLACE , DUNDEE, DD1 5NT
Energy rating
Current: 32 F | Potential: 78 C
Environmental impact (CO₂)
Current: 43
| Potential: 81
| Field | Value |
|---|---|
| Id | 4091397 |
| BUILDING REFERENCE NUMBER | 1000315302 |
| OSG REFERENCE NUMBER | 9059007792 |
| ADDRESS1 | 36H FOREST PARK PLACE |
| ADDRESS2 | — |
| ADDRESS3 | DUNDEE |
| POSTCODE | DD1 5NT |
| INSPECTION DATE | 2016-06-02 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-02 |
| ENERGY CONSUMPTION CURRENT | 625.00 |
| TOTAL FLOOR AREA | 38 |
| 3 YR ENERGY COST CURRENT | 3582.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 2508.0000 |
| CURRENT ENERGY EFFICIENCY | 32 |
| CURRENT ENERGY RATING | F |
| POTENTIAL ENERGY EFFICIENCY | 78 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 43 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 81 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 107.00 |
| IMPROVEMENTS | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 54; Energy Rating after improvement: E 54; Environmental Rating after improvement: D 64; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £30; Typical Saving: 10; Energy Rating after improvement: D 55; Environmental Rating after improvement: D 64; Green Deal Eligible: N | Description: Replacement glazing units; Indicative Cost: £1,000 - £1,400; Typical Saving: 31; Energy Rating after improvement: C 78; Environmental Rating after improvement: B 81; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 367; Energy Rating after improvement: E 51; Environmental Rating after improvement: D 61; Green Deal Eligible: Y | Description: Change heating to gas condensing boiler; Indicative Cost: £3,000 - £7,000; Typical Saving: 373; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 79; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor | Average |
| WALL ENV EFF | Poor | Average |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Room heaters, electric |
| MAINHEAT ENERGY EFF | Very Poor |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | Programmer and appliance thermostats |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, standard tariff |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 33% of fixed outlets |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.00 |
| CO2 EMISSIONS POTENTIAL | 2.70 |
| HEATING COST CURRENT | 2487.0000 |
| HEATING COST POTENTIAL | 687.0000 |
| HOT WATER COST CURRENT | 954.00 |
| HOT WATER COST POTENTIAL | 303.00 |
| LIGHTING COST CURRENT | 141.00 |
| LIGHTING COST POTENTIAL | 84.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | Description: Micro CHP | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 4431 |
| WATER HEATING DEMAND | 2073 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -2216 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 2.83 |
| DATA ZONE | S01001099 (Perth Road) |
| ENERGY CONSUMPTION POTENTIAL | 188.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 9 |
| LOW ENERGY FIXED LIGHT COUNT | 3 |
| LOW ENERGY LIGHTING | 33.00 |
| FLOOR LEVEL | mid floor |
| FLAT TOP STOREY | 02 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | Dundee City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | room heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2603 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 1 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | 6.28 |
| CONSTITUENCY | 00QJMC |
| CONSTITUENCY LABEL | West End |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01007694 (Perth Road - 06) |
| CREATED AT | 02/06/2016 16:33:28 |
| REPORT REFERENCE NUMBER | 2300-4123-0529-1000-1663 |
| Source file | Q2 2016.csv |
| Address display | 36H FOREST PARK PLACE , DUNDEE |
| Nation | scotland |