Energy Performance Certificate
1F3 , 242 LEITH WALK , EDINBURGH, EH6 5EL
Energy rating
Current: 53 E | Potential: 86 B
Environmental impact (CO₂)
Current: 58
| Potential: 77
| Field | Value |
|---|---|
| Id | 4091551 |
| BUILDING REFERENCE NUMBER | 1000360992 |
| OSG REFERENCE NUMBER | 906338855 |
| ADDRESS1 | 1F3 |
| ADDRESS2 | 242 LEITH WALK |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH6 5EL |
| INSPECTION DATE | 2016-06-30 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-30 |
| ENERGY CONSUMPTION CURRENT | 443.00 |
| TOTAL FLOOR AREA | 34 |
| 3 YR ENERGY COST CURRENT | 2274.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1602.0000 |
| CURRENT ENERGY EFFICIENCY | 53 |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY EFFICIENCY | 86 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 58 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 77 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 75.00 |
| IMPROVEMENTS | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £800 - £1,200; Typical Saving: 251; Energy Rating after improvement: B 81; Environmental Rating after improvement: D 68; Green Deal Eligible: Y | Description: Replace single glazed windows with low-E double glazed windows; Indicative Cost: £3,300 - £6,500; Typical Saving: 82; Energy Rating after improvement: B 86; Environmental Rating after improvement: C 77; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 202; Energy Rating after improvement: D 66; Environmental Rating after improvement: C 69; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor |
| WALL ENV EFF | Poor |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Single glazed |
| WINDOWS ENERGY EFF | Very Poor |
| WINDOWS ENV EFF | Very Poor |
| MAINHEAT DESCRIPTION | No system present: electric heaters assumed |
| MAINHEAT ENERGY EFF | Very Poor |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | None |
| MAINHEATC ENERGY EFF | Very Poor |
| MAINHEATC ENV EFF | Very Poor |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, standard tariff |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.50 |
| CO2 EMISSIONS POTENTIAL | 1.10 |
| HEATING COST CURRENT | 1572.0000 |
| HEATING COST POTENTIAL | 237.0000 |
| HOT WATER COST CURRENT | 624.00 |
| HOT WATER COST POTENTIAL | 348.00 |
| LIGHTING COST CURRENT | 78.00 |
| LIGHTING COST POTENTIAL | 87.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 3393 |
| WATER HEATING DEMAND | 1347 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -1305 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 2.6 |
| DATA ZONE | S01002254 (Bonnington and Pilrig) |
| ENERGY CONSUMPTION POTENTIAL | 243.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 5 |
| LOW ENERGY FIXED LIGHT COUNT | 5 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | mid floor |
| FLAT TOP STOREY | 01 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 0 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | none |
| MAIN FUEL | no heating/hot-water system or data is from a community network |
| MAIN HEATING CONTROLS | 2699 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | not defined |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | 4.8 |
| CONSTITUENCY | 00QPMM |
| CONSTITUENCY LABEL | Leith Walk |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01008815 (Pilrig - 03) |
| CREATED AT | 30/06/2016 16:48:05 |
| REPORT REFERENCE NUMBER | 2300-0609-0029-6079-1663 |
| Source file | Q2 2016.csv |
| Address display | 1F3 , 242 LEITH WALK , EDINBURGH |
| Nation | scotland |