Energy Performance Certificate
FLAT 1/1 , 92 PARK ROAD , GLASGOW, G4 9HB
Energy rating
Current: 70 C | Potential: 81 B
Environmental impact (CO₂)
Current: 69
| Potential: 85
| Field | Value |
|---|---|
| Id | 5124672 |
| BUILDING REFERENCE NUMBER | 1000877063 |
| OSG REFERENCE NUMBER | 906700089476 |
| ADDRESS1 | FLAT 1/1 |
| ADDRESS2 | 92 PARK ROAD |
| ADDRESS3 | GLASGOW |
| POSTCODE | G4 9HB |
| INSPECTION DATE | 2024-10-25 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2024-11-07 |
| ENERGY CONSUMPTION CURRENT | 234.00 |
| TOTAL FLOOR AREA | 60 |
| 3 YR ENERGY COST CURRENT | 2526.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1038.0000 |
| CURRENT ENERGY EFFICIENCY | 70 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 81 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 69 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 85 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 41.00 |
| IMPROVEMENTS | Description: Draughtproofing; Indicative Cost: £80 - £120; Typical Saving: 17; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 78; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 64; Energy Rating after improvement: C 79; Environmental Rating after improvement: B 81; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 182; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 77; Green Deal Eligible: Y | Description: Replace single glazed windows with low-E double glazed windows; Indicative Cost: £3,300 - £6,500; Typical Saving: 83; Energy Rating after improvement: B 81; Environmental Rating after improvement: B 85; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor | Poor |
| WALL ENV EFF | Poor | Poor |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Single glazed |
| WINDOWS ENERGY EFF | Very Poor |
| WINDOWS ENV EFF | Very Poor |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.50 |
| CO2 EMISSIONS POTENTIAL | 1.30 |
| HEATING COST CURRENT | 1887.0000 |
| HEATING COST POTENTIAL | 882.0000 |
| HOT WATER COST CURRENT | 432.00 |
| HOT WATER COST POTENTIAL | 396.00 |
| LIGHTING COST CURRENT | 207.00 |
| LIGHTING COST POTENTIAL | 210.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 5970 |
| WATER HEATING DEMAND | 1856 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -2339 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 3.21 |
| DATA ZONE | S01003487 (Woodlands) |
| ENERGY CONSUMPTION POTENTIAL | 116.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 12 |
| LOW ENERGY FIXED LIGHT COUNT | 12 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | mid floor |
| FLAT TOP STOREY | 01 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Glasgow City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | not defined |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | 6.83 |
| CONSTITUENCY | 00QSML |
| CONSTITUENCY LABEL | Hillhead |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01010291 (Woodlands - 03) |
| CREATED AT | 07/11/2024 08:23:21 |
| REPORT REFERENCE NUMBER | 2253-1908-6200-0274-7204 |
| Source file | Q4 2024.csv |
| Address display | FLAT 1/1 , 92 PARK ROAD , GLASGOW |
| Nation | scotland |