Energy Performance Certificate
10 Knoll Park Drive , GALASHIELS, TD1 2EP
Energy rating
Current: 83 B | Potential: 92 A
Environmental impact (CO₂)
Current: 84
| Potential: 93
| Field | Value |
|---|---|
| Id | 3789548 |
| BUILDING REFERENCE NUMBER | 1235326412 |
| OSG REFERENCE NUMBER | — |
| ADDRESS1 | 10 Knoll Park Drive |
| ADDRESS2 | — |
| ADDRESS3 | GALASHIELS |
| POSTCODE | TD1 2EP |
| INSPECTION DATE | 2019-03-27 |
| TYPE OF ASSESSMENT | SAP, new dwelling |
| LODGEMENT DATE | 2019-03-27 |
| ENERGY CONSUMPTION CURRENT | 106.00 |
| TOTAL FLOOR AREA | 116 |
| 3 YR ENERGY COST CURRENT | 1584.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 87.0000 |
| CURRENT ENERGY EFFICIENCY | 83 |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY EFFICIENCY | 92 |
| POTENTIAL ENERGY RATING | A |
| ENVIRONMENT IMPACT CURRENT | 84 |
| CURRENT ENVIRONMENTAL RATING | B |
| ENVIRONMENT IMPACT POTENTIAL | 93 |
| POTENTIAL ENVIRONMENTAL RATING | A |
| CO2 EMISS CURR PER FLOOR AREA | 19.00 |
| IMPROVEMENTS | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 278; Energy Rating after improvement: A 92; Environmental Rating after improvement: A 93; Green Deal Eligible: N | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 30; Energy Rating after improvement: B 84; Environmental Rating after improvement: B 85; Green Deal Eligible: N | |
| WALL DESCRIPTION | Average thermal transmittance 0.23 W/m²K |
| WALL ENERGY EFF | Very Good |
| WALL ENV EFF | Very Good |
| ROOF DESCRIPTION | Average thermal transmittance 0.17 W/m²K |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | Average thermal transmittance 0.18 W/m²K |
| FLOOR ENERGY EFF | Very Good |
| FLOOR ENV EFF | Very Good |
| WINDOWS DESCRIPTION | Description: High performance glazing |
| WINDOWS ENERGY EFF | Very Good |
| WINDOWS ENV EFF | Very Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | Air permeability 7.5 m³/h.m² (assessed average) |
| AIR TIGHTNESS ENERGY EFF | Good |
| AIR TIGHTNESS ENV EFF | Good |
| CO2 EMISSIONS CURRENT | 2.20 |
| CO2 EMISSIONS POTENTIAL | 1.10 |
| HEATING COST CURRENT | 1098.0000 |
| HEATING COST POTENTIAL | 1098.0000 |
| HOT WATER COST CURRENT | 252.00 |
| HOT WATER COST POTENTIAL | 165.00 |
| LIGHTING COST CURRENT | 234.00 |
| LIGHTING COST POTENTIAL | 234.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 5726 |
| WATER HEATING DEMAND | 1911 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | — |
| FLOOR HEIGHT | 2.64 |
| DATA ZONE | — |
| ENERGY CONSUMPTION POTENTIAL | 54.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 9 |
| LOW ENERGY FIXED LIGHT COUNT | 9 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 0 |
| NUMBER HABITABLE ROOMS | 0 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 0 |
| LOCAL AUTHORITY LABEL | — |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | Gas: mains gas |
| MAIN HEATING CONTROLS | 2110 |
| MECHANICAL VENTILATION | mechanical, supply and extract |
| ENERGY TARIFF | — |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | — |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | — |
| TENURE | owner-occupied |
| TRANSACTION TYPE | new dwelling |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | — |
| CONSTITUENCY LABEL | — |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Detached |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01012271 (Heriot - Fountainhall - Stow Landward) |
| CREATED AT | 27/03/2019 21:35:08 |
| REPORT REFERENCE NUMBER | 2211-1237-4530-2623-3922 |
| Source file | Q1 2019.csv |
| Address display | 10 Knoll Park Drive , GALASHIELS |
| Nation | scotland |