Energy Performance Certificate
65F MARKET STREET , FISHERROW , MUSSELBURGH, EH21 6PS
Energy rating
Current: 45 E | Potential: 65 D
Environmental impact (CO₂)
Current: 39
| Potential: 61
| Field | Value |
|---|---|
| Id | 5017323 |
| BUILDING REFERENCE NUMBER | 1000873978 |
| OSG REFERENCE NUMBER | 138004220 |
| ADDRESS1 | 65F MARKET STREET |
| ADDRESS2 | FISHERROW |
| ADDRESS3 | MUSSELBURGH |
| POSTCODE | EH21 6PS |
| INSPECTION DATE | 2021-10-26 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2021-10-28 |
| ENERGY CONSUMPTION CURRENT | 476.00 |
| TOTAL FLOOR AREA | 70 |
| 3 YR ENERGY COST CURRENT | 3495.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1263.0000 |
| CURRENT ENERGY EFFICIENCY | 45 |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY EFFICIENCY | 65 |
| POTENTIAL ENERGY RATING | D |
| ENVIRONMENT IMPACT CURRENT | 39 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 61 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 84.00 |
| IMPROVEMENTS | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 208; Energy Rating after improvement: D 65; Environmental Rating after improvement: D 61; Green Deal Eligible: Y | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 10; Energy Rating after improvement: E 52; Environmental Rating after improvement: E 45; Green Deal Eligible: Y | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 71; Energy Rating after improvement: D 55; Environmental Rating after improvement: E 48; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 132; Energy Rating after improvement: E 52; Environmental Rating after improvement: E 44; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor | Poor |
| WALL ENV EFF | Poor | Poor |
| ROOF DESCRIPTION | Pitched, no insulation (assumed) |
| ROOF ENERGY EFF | Very Poor |
| ROOF ENV EFF | Very Poor |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Average |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 5.90 |
| CO2 EMISSIONS POTENTIAL | 2.40 |
| HEATING COST CURRENT | 2772.0000 |
| HEATING COST POTENTIAL | 1743.0000 |
| HOT WATER COST CURRENT | 537.00 |
| HOT WATER COST POTENTIAL | 303.00 |
| LIGHTING COST CURRENT | 186.00 |
| LIGHTING COST POTENTIAL | 186.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Micro CHP | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 13058 |
| WATER HEATING DEMAND | 2724 |
| IMPACT LOFT INSULATION | -6668 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -2710 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 3 |
| DATA ZONE | S01001590 (IZ Nine) |
| ENERGY CONSUMPTION POTENTIAL | 280.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 11 |
| LOW ENERGY FIXED LIGHT COUNT | 11 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 03 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | East Lothian |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (private) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | 7.3 |
| CONSTITUENCY | 00QMMA |
| CONSTITUENCY LABEL | Musselburgh West |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01008183 (IZ04 - 02) |
| CREATED AT | 28/10/2021 16:32:45 |
| REPORT REFERENCE NUMBER | 2168-1908-7200-9039-7204 |
| Source file | Q4 2021.csv |
| Address display | 65F MARKET STREET , FISHERROW , MUSSELBURGH |
| Nation | scotland |