Energy Performance Certificate
FLAT 3/2 , 127 NOVAR DRIVE , GLASGOW, G12 9TA
Energy rating
Current: 55 D | Potential: 61 D
Environmental impact (CO₂)
Current: 42
| Potential: 51
| Field | Value |
|---|---|
| Id | 5051123 |
| BUILDING REFERENCE NUMBER | 1000805356 |
| OSG REFERENCE NUMBER | 906700082403 |
| ADDRESS1 | FLAT 3/2 |
| ADDRESS2 | 127 NOVAR DRIVE |
| ADDRESS3 | GLASGOW |
| POSTCODE | G12 9TA |
| INSPECTION DATE | 2022-10-25 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2022-10-27 |
| ENERGY CONSUMPTION CURRENT | 364.00 |
| TOTAL FLOOR AREA | 66 |
| 3 YR ENERGY COST CURRENT | 2874.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 429.0000 |
| CURRENT ENERGY EFFICIENCY | 55 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 61 |
| POTENTIAL ENERGY RATING | D |
| ENVIRONMENT IMPACT CURRENT | 42 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 51 |
| POTENTIAL ENVIRONMENTAL RATING | E |
| CO2 EMISS CURR PER FLOOR AREA | 77.00 |
| IMPROVEMENTS | Description: Replace single glazed windows with low-E double glazed windows; Indicative Cost: £3,300 - £6,500; Typical Saving: 48; Energy Rating after improvement: D 61; Environmental Rating after improvement: E 51; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 94; Energy Rating after improvement: D 59; Environmental Rating after improvement: E 48; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor | Poor |
| WALL ENV EFF | Poor | Poor |
| ROOF DESCRIPTION | Pitched, no insulation (assumed) |
| ROOF ENERGY EFF | Very Poor |
| ROOF ENV EFF | Very Poor |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Single glazed |
| WINDOWS ENERGY EFF | Very Poor |
| WINDOWS ENV EFF | Very Poor |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, coal |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 75% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 5.10 |
| CO2 EMISSIONS POTENTIAL | 0.90 |
| HEATING COST CURRENT | 2409.0000 |
| HEATING COST POTENTIAL | 1977.0000 |
| HOT WATER COST CURRENT | 234.00 |
| HOT WATER COST POTENTIAL | 234.00 |
| LIGHTING COST CURRENT | 231.00 |
| LIGHTING COST POTENTIAL | 234.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 12866 |
| WATER HEATING DEMAND | 1845 |
| IMPACT LOFT INSULATION | -5993 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -2196 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 3.17 |
| DATA ZONE | S01003552 (Kelvinside and Jordanhill) |
| ENERGY CONSUMPTION POTENTIAL | 300.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 12 |
| LOW ENERGY FIXED LIGHT COUNT | 9 |
| LOW ENERGY LIGHTING | 75.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 03 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Glasgow City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | not defined |
| NUMBER OPEN FIREPLACES | 1 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | 5.46 |
| CONSTITUENCY | 00QSML |
| CONSTITUENCY LABEL | Hillhead |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01010399 (Partickhill and Hyndland - 03) |
| CREATED AT | 27/10/2022 09:29:18 |
| REPORT REFERENCE NUMBER | 2156-1908-5200-3552-0200 |
| Source file | Q4 2022.csv |
| Address display | FLAT 3/2 , 127 NOVAR DRIVE , GLASGOW |
| Nation | scotland |