Energy Performance Certificate
4A SCALPAY TERRACE , OBAN, PA34 4YH
Energy rating
Current: 72 C | Potential: 78 C
Environmental impact (CO₂)
Current: 53
| Potential: 65
| Field | Value |
|---|---|
| Id | 3922637 |
| BUILDING REFERENCE NUMBER | 1001674249 |
| OSG REFERENCE NUMBER | 125023395 |
| ADDRESS1 | 4A SCALPAY TERRACE |
| ADDRESS2 | — |
| ADDRESS3 | OBAN |
| POSTCODE | PA34 4YH |
| INSPECTION DATE | 2023-01-27 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2023-02-11 |
| ENERGY CONSUMPTION CURRENT | 337.00 |
| TOTAL FLOOR AREA | 84 |
| 3 YR ENERGY COST CURRENT | 3723.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 903.0000 |
| CURRENT ENERGY EFFICIENCY | 72 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 78 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 53 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 65 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 57.00 |
| IMPROVEMENTS | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 64; Energy Rating after improvement: C 73; Environmental Rating after improvement: D 56; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 237; Energy Rating after improvement: C 78; Environmental Rating after improvement: D 65; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, partial insulation (assumed) | Cavity wall, with external insulation |
| WALL ENERGY EFF | Average | Good |
| WALL ENV EFF | Average | Good |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | Controls for high heat retention storage heaters |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Portable electric heaters (assumed) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 90% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.80 |
| CO2 EMISSIONS POTENTIAL | 1.20 |
| HEATING COST CURRENT | 2667.0000 |
| HEATING COST POTENTIAL | 1764.0000 |
| HOT WATER COST CURRENT | 747.00 |
| HOT WATER COST POTENTIAL | 747.00 |
| LIGHTING COST CURRENT | 309.00 |
| LIGHTING COST POTENTIAL | 309.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 6919 |
| WATER HEATING DEMAND | 1933 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | -495 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1965-1975 |
| FLOOR HEIGHT | 2.4 |
| DATA ZONE | S01000814 (Oban South) |
| ENERGY CONSUMPTION POTENTIAL | 252.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 10 |
| LOW ENERGY FIXED LIGHT COUNT | 9 |
| LOW ENERGY LIGHTING | 90.00 |
| FLOOR LEVEL | ground floor |
| FLAT TOP STOREY | 00 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Argyll and Bute |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric storage heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2404 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | ECO assessment |
| UNHEATED CORRIDOR LENGTH | 11.14 |
| CONSTITUENCY | 00QDMD |
| CONSTITUENCY LABEL | Oban South and the Isles |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01007293 (Oban South - 05) |
| CREATED AT | 11/02/2023 10:13:01 |
| REPORT REFERENCE NUMBER | 2139-1016-4209-2747-7204 |
| Source file | Q1 2023.csv |
| Address display | 4A SCALPAY TERRACE , OBAN |
| Nation | scotland |