Energy Performance Certificate
FLAT 1/2 , 95 LANGBAR CRESCENT , GLASGOW, G33 4JX
Energy rating
Current: 72 C | Potential: 79 C
Environmental impact (CO₂)
Current: 72
| Potential: 81
| Field | Value |
|---|---|
| Id | 4506348 |
| BUILDING REFERENCE NUMBER | 1001256219 |
| OSG REFERENCE NUMBER | 906700186857 |
| ADDRESS1 | FLAT 1/2 |
| ADDRESS2 | 95 LANGBAR CRESCENT |
| ADDRESS3 | GLASGOW |
| POSTCODE | G33 4JX |
| INSPECTION DATE | 2017-03-27 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2017-07-13 |
| ENERGY CONSUMPTION CURRENT | 226.00 |
| TOTAL FLOOR AREA | 54 |
| 3 YR ENERGY COST CURRENT | 1614.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 435.0000 |
| CURRENT ENERGY EFFICIENCY | 72 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 79 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 72 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 81 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 40.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £30; Typical Saving: 28; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 76; Green Deal Eligible: N | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 78; Energy Rating after improvement: C 79; Environmental Rating after improvement: B 81; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 40; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 75; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, no insulation (assumed) | Cavity wall, with external insulation |
| WALL ENERGY EFF | Average | Good |
| WALL ENV EFF | Average | Good |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 14% of fixed outlets |
| LIGHTING ENERGY EFF | Poor |
| LIGHTING ENV EFF | Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.20 |
| CO2 EMISSIONS POTENTIAL | 0.70 |
| HEATING COST CURRENT | 1080.0000 |
| HEATING COST POTENTIAL | 801.0000 |
| HOT WATER COST CURRENT | 312.00 |
| HOT WATER COST POTENTIAL | 258.00 |
| LIGHTING COST CURRENT | 222.00 |
| LIGHTING COST POTENTIAL | 120.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | Description: Micro CHP | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 4030 |
| WATER HEATING DEMAND | 1770 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | -677 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | 2.46 |
| DATA ZONE | S01003379 (North Barlanark and Easterhouse South) |
| ENERGY CONSUMPTION POTENTIAL | 154.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 7 |
| LOW ENERGY FIXED LIGHT COUNT | 1 |
| LOW ENERGY LIGHTING | 14.00 |
| FLOOR LEVEL | mid floor |
| FLAT TOP STOREY | 01 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Glasgow City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2111 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | none of the above |
| UNHEATED CORRIDOR LENGTH | 9.67 |
| CONSTITUENCY | 00QSMW |
| CONSTITUENCY LABEL | Baillieston |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01010118 (North Barlanark and Easterhouse South - 01) |
| CREATED AT | 13/07/2017 15:55:35 |
| REPORT REFERENCE NUMBER | 2139-1012-1207-2663-5904 |
| Source file | Q3 2017.csv |
| Address display | FLAT 1/2 , 95 LANGBAR CRESCENT , GLASGOW |
| Nation | scotland |