Energy Performance Certificate
50 HARBOUR STREET , HOPEMAN , ELGIN, IV30 5RU
Energy rating
Current: 50 E | Potential: 73 C
Environmental impact (CO₂)
Current: 42
| Potential: 65
| Field | Value |
|---|---|
| Id | 3808661 |
| BUILDING REFERENCE NUMBER | 1001576266 |
| OSG REFERENCE NUMBER | 133010512 |
| ADDRESS1 | 50 HARBOUR STREET |
| ADDRESS2 | HOPEMAN |
| ADDRESS3 | ELGIN |
| POSTCODE | IV30 5RU |
| INSPECTION DATE | 2020-01-27 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2020-01-28 |
| ENERGY CONSUMPTION CURRENT | 236.00 |
| TOTAL FLOOR AREA | 156 |
| 3 YR ENERGY COST CURRENT | 4743.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1536.0000 |
| CURRENT ENERGY EFFICIENCY | 50 |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY EFFICIENCY | 73 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 42 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 65 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 62.00 |
| IMPROVEMENTS | Description: Flat roof insulation; Indicative Cost: £850 - £1,500; Typical Saving: 126; Energy Rating after improvement: E 54; Environmental Rating after improvement: E 46; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 37; Energy Rating after improvement: D 67; Environmental Rating after improvement: D 59; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 304; Energy Rating after improvement: C 73; Environmental Rating after improvement: D 65; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 35; Energy Rating after improvement: D 55; Environmental Rating after improvement: E 47; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 130; Energy Rating after improvement: D 59; Environmental Rating after improvement: E 51; Green Deal Eligible: Y | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 57; Energy Rating after improvement: D 65; Environmental Rating after improvement: D 57; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 126; Energy Rating after improvement: D 63; Environmental Rating after improvement: D 55; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, partial insulation (assumed) | Sandstone or limestone, as built, no insulation (assumed) | Sandstone or limestone, with internal insulation |
| WALL ENERGY EFF | Average | Poor | Good |
| WALL ENV EFF | Average | Poor | Good |
| ROOF DESCRIPTION | Flat, limited insulation (assumed) | Pitched, no insulation (assumed) | Roof room(s), insulated (assumed) |
| ROOF ENERGY EFF | Poor | Very Poor | Good |
| ROOF ENV EFF | Poor | Very Poor | Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, oil |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Average |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Average |
| LIGHTING DESCRIPTION | Low energy lighting in 86% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 9.70 |
| CO2 EMISSIONS POTENTIAL | 4.20 |
| HEATING COST CURRENT | 3855.0000 |
| HEATING COST POTENTIAL | 2427.0000 |
| HOT WATER COST CURRENT | 555.00 |
| HOT WATER COST POTENTIAL | 447.00 |
| LIGHTING COST CURRENT | 333.00 |
| LIGHTING COST POTENTIAL | 333.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 22803 |
| WATER HEATING DEMAND | 3502 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | -630 |
| IMPACT SOLID WALL INSULATION | -2302 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 2.25 |
| DATA ZONE | S01004339 (IZ Twenty Two) |
| ENERGY CONSUMPTION POTENTIAL | 124.00 |
| EXTENSION COUNT | 1 |
| FIXED LIGHTING OUTLETS COUNT | 14 |
| LOW ENERGY FIXED LIGHT COUNT | 12 |
| LOW ENERGY LIGHTING | 86.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 8 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 8 |
| LOCAL AUTHORITY LABEL | Moray |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | oil (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 2 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QXME |
| CONSTITUENCY LABEL | Heldon and Laich |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Detached |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01011143 (Burghead, Roseisle and Laich - 02) |
| CREATED AT | 28/01/2020 12:00:02 |
| REPORT REFERENCE NUMBER | 2136-1015-6209-2060-7204 |
| Source file | Q1 2020.csv |
| Address display | 50 HARBOUR STREET , HOPEMAN , ELGIN |
| Nation | scotland |