Energy Performance Certificate

FLAT 1/2 , 14 PLANTATION SQUARE , GLASGOW, G51 1TG

EPC Report

Energy rating

Current: 81 B | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 81 B Current: 81 B 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 83 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 Current: 83 83 Potential: 83
Field Value
Id 3909811
BUILDING REFERENCE NUMBER 1000776328
OSG REFERENCE NUMBER 906700198788
ADDRESS1 FLAT 1/2
ADDRESS2 14 PLANTATION SQUARE
ADDRESS3 GLASGOW
POSTCODE G51 1TG
INSPECTION DATE 2023-03-20
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2023-03-20
ENERGY CONSUMPTION CURRENT 119.00
TOTAL FLOOR AREA 76
3 YR ENERGY COST CURRENT 2691.0000
3 YR ENERGY SAVINGS POTENTIAL 0.0000
CURRENT ENERGY EFFICIENCY 81
CURRENT ENERGY RATING B
POTENTIAL ENERGY EFFICIENCY 81
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 83
CURRENT ENVIRONMENTAL RATING B
ENVIRONMENT IMPACT POTENTIAL 83
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 21.00
IMPROVEMENTS
WALL DESCRIPTION Cavity wall, as built, partial insulation (assumed) | Cavity wall, with external insulation
WALL ENERGY EFF Average | Good
WALL ENV EFF Average | Good
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 88% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 1.60
CO2 EMISSIONS POTENTIAL 0.00
HEATING COST CURRENT 1533.0000
HEATING COST POTENTIAL 1533.0000
HOT WATER COST CURRENT 720.00
HOT WATER COST POTENTIAL 720.00
LIGHTING COST CURRENT 438.00
LIGHTING COST POTENTIAL 438.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 3192
WATER HEATING DEMAND 2070
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION -433
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1950-1964
FLOOR HEIGHT 2.3
DATA ZONE S01003348 (Kinning Park and Festival Park)
ENERGY CONSUMPTION POTENTIAL 119.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 7
LOW ENERGY LIGHTING 88.00
FLOOR LEVEL mid floor
FLAT TOP STOREY 01
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL Glasgow City
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH 9.3
CONSTITUENCY 00QSME
CONSTITUENCY LABEL Govan
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01009867 (Kinning Park and Festival Park - 02)
CREATED AT 20/03/2023 15:49:18
REPORT REFERENCE NUMBER 2108-1007-2207-3567-7204
Source file Q1 2023.csv
Address display FLAT 1/2 , 14 PLANTATION SQUARE , GLASGOW
Nation scotland