Energy Performance Certificate
36 KINTYRE CRESCENT , OLD MONKLAND , COATBRIDGE, ML5 5JT
Energy rating
Current: 75 C | Potential: 89 B
Environmental impact (CO₂)
Current: 75
| Potential: 88
| Field | Value |
|---|---|
| Id | 3862577 |
| BUILDING REFERENCE NUMBER | 1000377292 |
| OSG REFERENCE NUMBER | 118109289 |
| ADDRESS1 | 36 KINTYRE CRESCENT |
| ADDRESS2 | OLD MONKLAND |
| ADDRESS3 | COATBRIDGE |
| POSTCODE | ML5 5JT |
| INSPECTION DATE | 2022-02-08 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2022-02-08 |
| ENERGY CONSUMPTION CURRENT | 186.00 |
| TOTAL FLOOR AREA | 64 |
| 3 YR ENERGY COST CURRENT | 1506.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 66.0000 |
| CURRENT ENERGY EFFICIENCY | 75 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 89 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 75 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 88 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 33.00 |
| IMPROVEMENTS | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 315; Energy Rating after improvement: B 89; Environmental Rating after improvement: B 88; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 22; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 77; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 300 mm loft insulation |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| FLOOR DESCRIPTION | Suspended, insulated (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.10 |
| CO2 EMISSIONS POTENTIAL | 1.00 |
| HEATING COST CURRENT | 1080.0000 |
| HEATING COST POTENTIAL | 1080.0000 |
| HOT WATER COST CURRENT | 243.00 |
| HOT WATER COST POTENTIAL | 177.00 |
| LIGHTING COST CURRENT | 183.00 |
| LIGHTING COST POTENTIAL | 183.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 5763 |
| WATER HEATING DEMAND | 1989 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1999-2002 |
| FLOOR HEIGHT | 2.38 |
| DATA ZONE | S01004730 (Kirkshaws) |
| ENERGY CONSUMPTION POTENTIAL | 95.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 10 |
| LOW ENERGY FIXED LIGHT COUNT | 10 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | North Lanarkshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QZMJ |
| CONSTITUENCY LABEL | Coatbridge West |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01011563 (Kirkshaws - 02) |
| CREATED AT | 08/02/2022 17:21:08 |
| REPORT REFERENCE NUMBER | 2012-9722-2000-0718-3206 |
| Source file | Q1 2022.csv |
| Address display | 36 KINTYRE CRESCENT , OLD MONKLAND , COATBRIDGE |
| Nation | scotland |