Energy Performance Certificate

36 BANKHOLM PLACE , BUSBY , GLASGOW, G76 8SH

EPC Report

Energy rating

Current: 73 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 60 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 Current: 60 67 Potential: 67
Field Value
Id 4674038
BUILDING REFERENCE NUMBER 1000217342
OSG REFERENCE NUMBER 131025136
ADDRESS1 36 BANKHOLM PLACE
ADDRESS2 BUSBY
ADDRESS3 GLASGOW
POSTCODE G76 8SH
INSPECTION DATE 2022-09-13
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2022-09-14
ENERGY CONSUMPTION CURRENT 305.00
TOTAL FLOOR AREA 78
3 YR ENERGY COST CURRENT 3030.0000
3 YR ENERGY SAVINGS POTENTIAL 822.0000
CURRENT ENERGY EFFICIENCY 73
CURRENT ENERGY RATING C
POTENTIAL ENERGY EFFICIENCY 80
POTENTIAL ENERGY RATING C
ENVIRONMENT IMPACT CURRENT 60
CURRENT ENVIRONMENTAL RATING D
ENVIRONMENT IMPACT POTENTIAL 67
POTENTIAL ENVIRONMENTAL RATING D
CO2 EMISS CURR PER FLOOR AREA 52.00
IMPROVEMENTS Description: Increase hot water cylinder insulation; Indicative Cost: £15 - £30; Typical Saving: 38; Energy Rating after improvement: C 75; Environmental Rating after improvement: D 64; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £10; Typical Saving: 16; Energy Rating after improvement: C 76; Environmental Rating after improvement: D 64; Green Deal Eligible: N | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 61; Energy Rating after improvement: C 74; Environmental Rating after improvement: D 62; Green Deal Eligible: Y | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £1,200 - £1,800; Typical Saving: 159; Energy Rating after improvement: C 80; Environmental Rating after improvement: D 67; Green Deal Eligible: Y |
WALL DESCRIPTION Cavity wall, filled cavity | Solid brick, as built, partial insulation (assumed)
WALL ENERGY EFF Average | Average
WALL ENV EFF Average | Average
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 4.00
CO2 EMISSIONS POTENTIAL 0.70
HEATING COST CURRENT 1704.0000
HEATING COST POTENTIAL 1311.0000
HOT WATER COST CURRENT 1020.00
HOT WATER COST POTENTIAL 660.00
LIGHTING COST CURRENT 306.00
LIGHTING COST POTENTIAL 237.00
ALTERNATIVE IMPROVEMENTS Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 4719
WATER HEATING DEMAND 2571
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION -510
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1965-1975
FLOOR HEIGHT 2.4
DATA ZONE S01001694 (Busby)
ENERGY CONSUMPTION POTENTIAL 248.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
LOW ENERGY LIGHTING 71.00
FLOOR LEVEL mid floor
FLAT TOP STOREY 01
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL East Renfrewshire
MAINS GAS FLAG
MAIN HEATING CATEGORY electric storage heaters
MAIN FUEL electricity (not community)
MAIN HEATING CONTROLS 2402
MECHANICAL VENTILATION natural
ENERGY TARIFF dual
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH 5.3
CONSTITUENCY 00QNMF
CONSTITUENCY LABEL Busby, Clarkston and Eaglesham
WIND TURBINE COUNT 0
BUILT FORM Enclosed End-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01008368 (Busby - 03)
CREATED AT 14/09/2022 11:08:00
REPORT REFERENCE NUMBER 2012-4121-3000-0787-2292
Source file Q3 2022.csv
Address display 36 BANKHOLM PLACE , BUSBY , GLASGOW
Nation scotland