Energy Performance Certificate

65 MYRESIDE CIRCLE , ELGIN, IV30 4PR

EPC Report

Energy rating

Current: 68 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 D Current: 68 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 67 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 Current: 67 80 Potential: 80
Field Value
Id 5104947
BUILDING REFERENCE NUMBER 1002544207
OSG REFERENCE NUMBER 133033535
ADDRESS1 65 MYRESIDE CIRCLE
ADDRESS2
ADDRESS3 ELGIN
POSTCODE IV30 4PR
INSPECTION DATE 2023-10-20
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2023-10-20
ENERGY CONSUMPTION CURRENT 220.00
TOTAL FLOOR AREA 96
3 YR ENERGY COST CURRENT 6162.0000
3 YR ENERGY SAVINGS POTENTIAL 741.0000
CURRENT ENERGY EFFICIENCY 68
CURRENT ENERGY RATING D
POTENTIAL ENERGY EFFICIENCY 81
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 67
CURRENT ENVIRONMENTAL RATING D
ENVIRONMENT IMPACT POTENTIAL 80
POTENTIAL ENVIRONMENTAL RATING C
CO2 EMISS CURR PER FLOOR AREA 39.00
IMPROVEMENTS Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 132; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 71; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 611; Energy Rating after improvement: B 81; Environmental Rating after improvement: C 80; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 115; Energy Rating after improvement: C 70; Environmental Rating after improvement: C 69; Green Deal Eligible: Y |
WALL DESCRIPTION Timber frame, as built, insulated (assumed)
WALL ENERGY EFF Good
WALL ENV EFF Good
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
FLOOR DESCRIPTION Suspended, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 3.70
CO2 EMISSIONS POTENTIAL 1.40
HEATING COST CURRENT 4611.0000
HEATING COST POTENTIAL 4341.0000
HOT WATER COST CURRENT 1098.00
HOT WATER COST POTENTIAL 627.00
LIGHTING COST CURRENT 453.00
LIGHTING COST POTENTIAL 453.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 9932
WATER HEATING DEMAND 3070
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1992-1998
FLOOR HEIGHT 2.4
DATA ZONE S01004316 (IZ Eighteen)
ENERGY CONSUMPTION POTENTIAL 137.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 16
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 1
NUMBER HABITABLE ROOMS 5
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 5
LOCAL AUTHORITY LABEL Moray
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE rented (social)
TRANSACTION TYPE rental
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QXMF
CONSTITUENCY LABEL Elgin City North
WIND TURBINE COUNT 0
BUILT FORM Semi-Detached
PROPERTY TYPE House
DATA ZONE 2011 S01011127 (Elgin Bishopmill West and Newfield - 02)
CREATED AT 20/10/2023 13:43:33
REPORT REFERENCE NUMBER 2007-1925-0200-2247-4200
Source file Q4 2023.csv
Address display 65 MYRESIDE CIRCLE , ELGIN
Nation scotland