Energy Performance Certificate
18 APPLETON DRIVE , ELIBURN , LIVINGSTON, EH54 6FP
Energy rating
Current: 79 C | Potential: 90 B
Environmental impact (CO₂)
Current: 78
| Potential: 89
| Field | Value |
|---|---|
| Id | 3938011 |
| BUILDING REFERENCE NUMBER | 1234974192 |
| OSG REFERENCE NUMBER | 135042514 |
| ADDRESS1 | 18 APPLETON DRIVE |
| ADDRESS2 | ELIBURN |
| ADDRESS3 | LIVINGSTON |
| POSTCODE | EH54 6FP |
| INSPECTION DATE | 2023-03-20 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2023-03-20 |
| ENERGY CONSUMPTION CURRENT | 142.00 |
| TOTAL FLOOR AREA | 108 |
| 3 YR ENERGY COST CURRENT | 4284.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 531.0000 |
| CURRENT ENERGY EFFICIENCY | 79 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 90 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 78 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 89 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 25.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £30; Typical Saving: 71; Energy Rating after improvement: C 80; Environmental Rating after improvement: C 79; Green Deal Eligible: N | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 107; Energy Rating after improvement: B 81; Environmental Rating after improvement: B 82; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 606; Energy Rating after improvement: B 90; Environmental Rating after improvement: B 89; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALL ENERGY EFF | Very Good |
| WALL ENV EFF | Very Good |
| ROOF DESCRIPTION | Pitched, 300 mm loft insulation |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| FLOOR DESCRIPTION | Solid, insulated (assumed) | To unheated space, insulated (assumed) |
| FLOOR ENERGY EFF | N/A | N/A |
| FLOOR ENV EFF | N/A | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 50% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.70 |
| CO2 EMISSIONS POTENTIAL | 1.20 |
| HEATING COST CURRENT | 2691.0000 |
| HEATING COST POTENTIAL | 2754.0000 |
| HOT WATER COST CURRENT | 843.00 |
| HOT WATER COST POTENTIAL | 498.00 |
| LIGHTING COST CURRENT | 750.00 |
| LIGHTING COST POTENTIAL | 501.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 6792 |
| WATER HEATING DEMAND | 2463 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | — |
| FLOOR HEIGHT | 2.31 |
| DATA ZONE | — |
| ENERGY CONSUMPTION POTENTIAL | 77.00 |
| EXTENSION COUNT | 1 |
| FIXED LIGHTING OUTLETS COUNT | 12 |
| LOW ENERGY FIXED LIGHT COUNT | 6 |
| LOW ENERGY LIGHTING | 50.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 6 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 6 |
| LOCAL AUTHORITY LABEL | — |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | — |
| CONSTITUENCY LABEL | — |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Detached |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01013315 (Livingston Village and Eliburn South - 01) |
| CREATED AT | 20/03/2023 18:58:51 |
| REPORT REFERENCE NUMBER | 2002-1049-9237-1547-7224 |
| Source file | Q1 2023.csv |
| Address display | 18 APPLETON DRIVE , ELIBURN , LIVINGSTON |
| Nation | scotland |