Energy Performance Certificate

1 LANCASTER COURT , HARBOUR STREET , ELGIN, IV30 5RU

EPC Report

Energy rating

Current: 43 E | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 E Current: 43 E 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 39 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 Current: 39 80 Potential: 80
Field Value
Id 4737027
BUILDING REFERENCE NUMBER 1001576292
OSG REFERENCE NUMBER 133010510
ADDRESS1 1 LANCASTER COURT
ADDRESS2 HARBOUR STREET
ADDRESS3 ELGIN
POSTCODE IV30 5RU
INSPECTION DATE 2023-09-20
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2023-09-20
ENERGY CONSUMPTION CURRENT 285.00
TOTAL FLOOR AREA 132
3 YR ENERGY COST CURRENT 8964.0000
3 YR ENERGY SAVINGS POTENTIAL 5160.0000
CURRENT ENERGY EFFICIENCY 43
CURRENT ENERGY RATING E
POTENTIAL ENERGY EFFICIENCY 85
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 39
CURRENT ENVIRONMENTAL RATING E
ENVIRONMENT IMPACT POTENTIAL 80
POTENTIAL ENVIRONMENTAL RATING C
CO2 EMISS CURR PER FLOOR AREA 70.00
IMPROVEMENTS Description: Low energy lighting for all fixed outlets; Indicative Cost: £25; Typical Saving: 49; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 70; Green Deal Eligible: N | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 276; Energy Rating after improvement: C 71; Environmental Rating after improvement: D 66; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 126; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 69; Green Deal Eligible: Y | Description: Room-in-roof insulation; Indicative Cost: £1,500 - £2,700; Typical Saving: 1166; Energy Rating after improvement: D 66; Environmental Rating after improvement: D 60; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 104; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 74; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 611; Energy Rating after improvement: B 85; Environmental Rating after improvement: C 80; Green Deal Eligible: Y |
WALL DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALL ENERGY EFF Poor
WALL ENV EFF Poor
ROOF DESCRIPTION Roof room(s), no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 72% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 9.30
CO2 EMISSIONS POTENTIAL 6.50
HEATING COST CURRENT 7206.0000
HEATING COST POTENTIAL 2682.0000
HOT WATER COST CURRENT 963.00
HOT WATER COST POTENTIAL 498.00
LIGHTING COST CURRENT 795.00
LIGHTING COST POTENTIAL 624.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 20576
WATER HEATING DEMAND 3657
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION -1953
ADDENDUM TEXT
CONSTRUCTION AGE BAND before 1919
FLOOR HEIGHT 2.29
DATA ZONE S01004339 (IZ Twenty Two)
ENERGY CONSUMPTION POTENTIAL 76.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 13
LOW ENERGY LIGHTING 72.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 4
NUMBER HABITABLE ROOMS 5
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL Moray
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL oil (not community)
MAIN HEATING CONTROLS 2107
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE none of the above
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QXME
CONSTITUENCY LABEL Heldon and Laich
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE House
DATA ZONE 2011 S01011143 (Burghead, Roseisle and Laich - 02)
CREATED AT 20/09/2023 13:54:59
REPORT REFERENCE NUMBER 2002-1015-9201-2667-7204
Source file Q3 2023.csv
Address display 1 LANCASTER COURT , HARBOUR STREET , ELGIN
Nation scotland