Energy Performance Certificate
81 MILLER STREET , INVERNESS, IV2 3DN
Energy rating
Current: 64 D | Potential: 71 C
Environmental impact (CO₂)
Current: 58
| Potential: 65
| Field | Value |
|---|---|
| Id | 4132630 |
| BUILDING REFERENCE NUMBER | 1001034470 |
| OSG REFERENCE NUMBER | 130033134 |
| ADDRESS1 | 81 MILLER STREET |
| ADDRESS2 | — |
| ADDRESS3 | INVERNESS |
| POSTCODE | IV2 3DN |
| INSPECTION DATE | 2017-04-20 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2017-04-21 |
| ENERGY CONSUMPTION CURRENT | 434.00 |
| TOTAL FLOOR AREA | 38 |
| 3 YR ENERGY COST CURRENT | 1893.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 348.0000 |
| CURRENT ENERGY EFFICIENCY | 64 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 71 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 58 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 65 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 73.00 |
| IMPROVEMENTS | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 21; Energy Rating after improvement: C 69; Environmental Rating after improvement: D 63; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £20; Typical Saving: 15; Energy Rating after improvement: C 70; Environmental Rating after improvement: D 64; Green Deal Eligible: N | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 61; Energy Rating after improvement: D 67; Environmental Rating after improvement: D 62; Green Deal Eligible: Y | Description: High performance external doors; Indicative Cost: £500; Typical Saving: 19; Energy Rating after improvement: C 71; Environmental Rating after improvement: D 65; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | Suspended, limited insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Poor |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Manual charge control |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 33% of fixed outlets |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.80 |
| CO2 EMISSIONS POTENTIAL | 0.50 |
| HEATING COST CURRENT | 1053.0000 |
| HEATING COST POTENTIAL | 858.0000 |
| HOT WATER COST CURRENT | 678.00 |
| HOT WATER COST POTENTIAL | 591.00 |
| LIGHTING COST CURRENT | 162.00 |
| LIGHTING COST POTENTIAL | 96.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 3378 |
| WATER HEATING DEMAND | 1694 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1992-1998 |
| FLOOR HEIGHT | 2.38 |
| DATA ZONE | S01003792 (Inverness Inshes and Slackbuie) |
| ENERGY CONSUMPTION POTENTIAL | 355.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 2 |
| LOW ENERGY LIGHTING | 33.00 |
| FLOOR LEVEL | ground floor |
| FLAT TOP STOREY | 00 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | no corridor |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | Highland |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric storage heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2401 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (private) |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QTMW |
| CONSTITUENCY LABEL | Inverness South |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Maisonette |
| DATA ZONE 2011 | S01010592 (Inverness Inshes - 03) |
| CREATED AT | 21/04/2017 15:34:32 |
| REPORT REFERENCE NUMBER | 2000-1010-7204-4243-3900 |
| Source file | Q2 2017.csv |
| Address display | 81 MILLER STREET , INVERNESS |
| Nation | scotland |