Energy Performance Certificate
4 Tower Ridge Courtyard , Torlundy , Fort William, PH33 6SW
Energy rating
Current: 86 B | Potential: 95 A
Environmental impact (CO₂)
Current: 87
| Potential: 95
| Field | Value |
|---|---|
| Id | 4119647 |
| BUILDING REFERENCE NUMBER | 1234981601 |
| OSG REFERENCE NUMBER | — |
| ADDRESS1 | 4 Tower Ridge Courtyard |
| ADDRESS2 | Torlundy |
| ADDRESS3 | Fort William |
| POSTCODE | PH33 6SW |
| INSPECTION DATE | 2016-06-06 |
| TYPE OF ASSESSMENT | SAP, new dwelling |
| LODGEMENT DATE | 2016-06-06 |
| ENERGY CONSUMPTION CURRENT | 74.00 |
| TOTAL FLOOR AREA | 152 |
| 3 YR ENERGY COST CURRENT | 1689.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 243.0000 |
| CURRENT ENERGY EFFICIENCY | 86 |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY EFFICIENCY | 95 |
| POTENTIAL ENERGY RATING | A |
| ENVIRONMENT IMPACT CURRENT | 87 |
| CURRENT ENVIRONMENTAL RATING | B |
| ENVIRONMENT IMPACT POTENTIAL | 95 |
| POTENTIAL ENVIRONMENTAL RATING | A |
| CO2 EMISS CURR PER FLOOR AREA | 13.00 |
| IMPROVEMENTS | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 233; Energy Rating after improvement: A 95; Environmental Rating after improvement: A 95; Green Deal Eligible: N | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 80; Energy Rating after improvement: B 88; Environmental Rating after improvement: B 89; Green Deal Eligible: N | |
| WALL DESCRIPTION | Average thermal transmittance 0.19 W/m²K |
| WALL ENERGY EFF | Very Good |
| WALL ENV EFF | Very Good |
| ROOF DESCRIPTION | Average thermal transmittance 0.13 W/m²K |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| FLOOR DESCRIPTION | Average thermal transmittance 0.15 W/m²K |
| FLOOR ENERGY EFF | Very Good |
| FLOOR ENV EFF | Very Good |
| WINDOWS DESCRIPTION | Description: High performance glazing |
| WINDOWS ENERGY EFF | Very Good |
| WINDOWS ENV EFF | Very Good |
| MAINHEAT DESCRIPTION | Air source heat pump, underfloor, electric |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Very Good |
| MAINHEATCONT DESCRIPTION | Programmer and room thermostat |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | Air permeability 7.3 m³/h.m² (assumed) |
| AIR TIGHTNESS ENERGY EFF | Average |
| AIR TIGHTNESS ENV EFF | Average |
| CO2 EMISSIONS CURRENT | 1.90 |
| CO2 EMISSIONS POTENTIAL | 1.10 |
| HEATING COST CURRENT | 741.0000 |
| HEATING COST POTENTIAL | 741.0000 |
| HOT WATER COST CURRENT | 702.00 |
| HOT WATER COST POTENTIAL | 459.00 |
| LIGHTING COST CURRENT | 246.00 |
| LIGHTING COST POTENTIAL | 246.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | Description: Air source heat pump | |
| SPACE HEATING DEMAND | 5296 |
| WATER HEATING DEMAND | 2449 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | — |
| FLOOR HEIGHT | 2.4 |
| DATA ZONE | S01003741 (Lochaber West) |
| ENERGY CONSUMPTION POTENTIAL | 33.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 15 |
| LOW ENERGY FIXED LIGHT COUNT | 15 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 0 |
| NUMBER HABITABLE ROOMS | 0 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 0 |
| LOCAL AUTHORITY LABEL | Highland |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | heat pump with radiators or underfloor heating |
| MAIN FUEL | Electricity: electricity, unspecified tariff |
| MAIN HEATING CONTROLS | 2204 |
| MECHANICAL VENTILATION | mechanical, supply and extract |
| ENERGY TARIFF | — |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | — |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | — |
| TENURE | owner-occupied |
| TRANSACTION TYPE | new dwelling |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QTMY |
| CONSTITUENCY LABEL | Fort William and Ardnamurchan |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01010509 (Lochaber West - 06) |
| CREATED AT | 06/06/2016 11:38:41 |
| REPORT REFERENCE NUMBER | 1902-3866-3139-5400-1663 |
| Source file | Q2 2016.csv |
| Address display | 4 Tower Ridge Courtyard , Torlundy , Fort William |
| Nation | scotland |