Energy Performance Certificate
84 WATERMILL ROAD , FRASERBURGH, AB43 9RJ
Energy rating
Current: 57 D | Potential: 87 B
Environmental impact (CO₂)
Current: 49
| Potential: 86
| Field | Value |
|---|---|
| Id | 4105026 |
| BUILDING REFERENCE NUMBER | 1001651031 |
| OSG REFERENCE NUMBER | 151013996 |
| ADDRESS1 | 84 WATERMILL ROAD |
| ADDRESS2 | — |
| ADDRESS3 | FRASERBURGH |
| POSTCODE | AB43 9RJ |
| INSPECTION DATE | 2016-06-07 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-07 |
| ENERGY CONSUMPTION CURRENT | 372.00 |
| TOTAL FLOOR AREA | 94 |
| 3 YR ENERGY COST CURRENT | 4119.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 2052.0000 |
| CURRENT ENERGY EFFICIENCY | 57 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 87 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 49 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 86 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 66.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £40; Typical Saving: 32; Energy Rating after improvement: D 67; Environmental Rating after improvement: D 62; Green Deal Eligible: N | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 38; Energy Rating after improvement: D 65; Environmental Rating after improvement: D 60; Green Deal Eligible: Y | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 15; Energy Rating after improvement: D 66; Environmental Rating after improvement: D 61; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 329; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 75; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 44; Energy Rating after improvement: C 78; Environmental Rating after improvement: C 77; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 224; Energy Rating after improvement: D 64; Environmental Rating after improvement: D 58; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 259; Energy Rating after improvement: B 87; Environmental Rating after improvement: B 86; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Granite or whinstone, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor |
| WALL ENV EFF | Poor |
| ROOF DESCRIPTION | Pitched, 300 mm loft insulation |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A | N/A |
| FLOOR ENV EFF | N/A | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system, no cylinder thermostat |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 33% of fixed outlets |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 6.20 |
| CO2 EMISSIONS POTENTIAL | 4.30 |
| HEATING COST CURRENT | 3000.0000 |
| HEATING COST POTENTIAL | 1650.0000 |
| HOT WATER COST CURRENT | 816.00 |
| HOT WATER COST POTENTIAL | 237.00 |
| LIGHTING COST CURRENT | 303.00 |
| LIGHTING COST POTENTIAL | 180.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | Description: Micro CHP | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 12435 |
| WATER HEATING DEMAND | 3570 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -3190 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | 2.57 |
| DATA ZONE | S01000564 (Fraserburgh Harbour and Broadsea) |
| ENERGY CONSUMPTION POTENTIAL | 115.00 |
| EXTENSION COUNT | 1 |
| FIXED LIGHTING OUTLETS COUNT | 12 |
| LOW ENERGY FIXED LIGHT COUNT | 4 |
| LOW ENERGY LIGHTING | 33.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 5 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 5 |
| LOCAL AUTHORITY LABEL | Aberdeenshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QBMC |
| CONSTITUENCY LABEL | Fraserburgh and District |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01007126 (Fraserburgh Harbour and Broadsea - 02) |
| CREATED AT | 07/06/2016 14:26:29 |
| REPORT REFERENCE NUMBER | 1600-1530-0129-0103-1663 |
| Source file | Q2 2016.csv |
| Address display | 84 WATERMILL ROAD , FRASERBURGH |
| Nation | scotland |