Energy Performance Certificate

9 KINGSLAW AVENUE , KIRKCALDY, KY1 2DD

EPC Report

Energy rating

Current: 88 B | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 B Current: 88 B 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 91 | Potential: 94
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 91 Current: 91 94 Potential: 94
Field Value
Id 4404595
BUILDING REFERENCE NUMBER 1236260841
OSG REFERENCE NUMBER 320333958
ADDRESS1 9 KINGSLAW AVENUE
ADDRESS2
ADDRESS3 KIRKCALDY
POSTCODE KY1 2DD
INSPECTION DATE 2024-05-30
TYPE OF ASSESSMENT SAP, new dwelling
LODGEMENT DATE 2024-05-30
ENERGY CONSUMPTION CURRENT 73.00
TOTAL FLOOR AREA 57
3 YR ENERGY COST CURRENT 1536.0000
3 YR ENERGY SAVINGS POTENTIAL 156.0000
CURRENT ENERGY EFFICIENCY 88
CURRENT ENERGY RATING B
POTENTIAL ENERGY EFFICIENCY 89
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 91
CURRENT ENVIRONMENTAL RATING B
ENVIRONMENT IMPACT POTENTIAL 94
POTENTIAL ENVIRONMENTAL RATING A
CO2 EMISS CURR PER FLOOR AREA 13.00
IMPROVEMENTS Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 52; Energy Rating after improvement: B 89; Environmental Rating after improvement: A 94; Green Deal Eligible: N |
WALL DESCRIPTION Average thermal transmittance 0.19 W/m²K
WALL ENERGY EFF Very Good
WALL ENV EFF Very Good
ROOF DESCRIPTION Average thermal transmittance 0.14 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.18 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION Description: High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION Air permeability 5.6 m³/h.m² (as tested)
AIR TIGHTNESS ENERGY EFF Good
AIR TIGHTNESS ENV EFF Good
CO2 EMISSIONS CURRENT 0.70
CO2 EMISSIONS POTENTIAL 0.10
HEATING COST CURRENT 876.0000
HEATING COST POTENTIAL 876.0000
HOT WATER COST CURRENT 381.00
HOT WATER COST POTENTIAL 225.00
LIGHTING COST CURRENT 279.00
LIGHTING COST POTENTIAL 279.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES Description: Solar photovoltaics |
SPACE HEATING DEMAND 1941
WATER HEATING DEMAND 1480
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND
FLOOR HEIGHT 2.3
DATA ZONE
ENERGY CONSUMPTION POTENTIAL 56.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 0
NUMBER HABITABLE ROOMS 0
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 0
LOCAL AUTHORITY LABEL
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL Gas: mains gas
MAIN HEATING CONTROLS 2110
MECHANICAL VENTILATION mechanical, supply and extract
ENERGY TARIFF
MULTI GLAZE PROPORTION 0
GLAZED TYPE
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Peak Power: 0.68000000; Orientation: South West; Pitch: 30 degrees; Overshading: none or very little; Connection: connected to dwelling’s electricity meter; |
SOLAR WATER HEATING FLAG
TENURE owner-occupied
TRANSACTION TYPE new dwelling
UNHEATED CORRIDOR LENGTH
CONSTITUENCY
CONSTITUENCY LABEL
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE House
DATA ZONE 2011 S01009534 (Sinclairtown Central)
CREATED AT 30/05/2024 10:37:44
REPORT REFERENCE NUMBER 1414-4635-8630-2000-2272
Source file Q2 2024.csv
Address display 9 KINGSLAW AVENUE , KIRKCALDY
Nation scotland