Energy Performance Certificate

DE KINDEREN LODGE , 39 HILLHEAD DRIVE , ELLON, AB41 9WB

EPC Report

Energy rating

Current: 65 D | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 65 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 87 Potential: 87
Field Value
Id 4089314
BUILDING REFERENCE NUMBER 1000137411
OSG REFERENCE NUMBER 151034042
ADDRESS1 DE KINDEREN LODGE
ADDRESS2 39 HILLHEAD DRIVE
ADDRESS3 ELLON
POSTCODE AB41 9WB
INSPECTION DATE 2016-06-08
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2016-06-08
ENERGY CONSUMPTION CURRENT 295.00
TOTAL FLOOR AREA 61
3 YR ENERGY COST CURRENT 2406.0000
3 YR ENERGY SAVINGS POTENTIAL 642.0000
CURRENT ENERGY EFFICIENCY 65
CURRENT ENERGY RATING D
POTENTIAL ENERGY EFFICIENCY 86
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 65
CURRENT ENVIRONMENTAL RATING D
ENVIRONMENT IMPACT POTENTIAL 87
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 52.00
IMPROVEMENTS Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 32; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 74; Green Deal Eligible: Y | Description: Increase loft insulation to 270 mm; Indicative Cost: £100 - £350; Typical Saving: 25; Energy Rating after improvement: D 66; Environmental Rating after improvement: D 66; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 82; Energy Rating after improvement: C 69; Environmental Rating after improvement: C 70; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £55; Typical Saving: 30; Energy Rating after improvement: C 70; Environmental Rating after improvement: C 71; Green Deal Eligible: N | Description: Replacement glazing units; Indicative Cost: £1,000 - £1,400; Typical Saving: 47; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 76; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 250; Energy Rating after improvement: B 86; Environmental Rating after improvement: B 87; Green Deal Eligible: Y |
WALL DESCRIPTION Timber frame, as built, partial insulation (assumed)
WALL ENERGY EFF Average
WALL ENV EFF Average
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 15% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 3.20
CO2 EMISSIONS POTENTIAL 1.90
HEATING COST CURRENT 1887.0000
HEATING COST POTENTIAL 1446.0000
HOT WATER COST CURRENT 285.00
HOT WATER COST POTENTIAL 189.00
LIGHTING COST CURRENT 234.00
LIGHTING COST POTENTIAL 129.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 8673
WATER HEATING DEMAND 1879
IMPACT LOFT INSULATION -431
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1965-1975
FLOOR HEIGHT 2.35
DATA ZONE S01000429 (Ellon East)
ENERGY CONSUMPTION POTENTIAL 122.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 2
LOW ENERGY LIGHTING 15.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL Aberdeenshire
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QBMJ
CONSTITUENCY LABEL Ellon and District
WIND TURBINE COUNT 0
BUILT FORM Semi-Detached
PROPERTY TYPE Bungalow
DATA ZONE 2011 S01006962 (Ellon East - 05)
CREATED AT 08/06/2016 12:17:54
REPORT REFERENCE NUMBER 1100-0384-0729-3001-1663
Source file Q2 2016.csv
Address display DE KINDEREN LODGE , 39 HILLHEAD DRIVE , ELLON
Nation scotland