Energy Performance Certificate

43 ANDERSON STREET , KELLOHOLM , SANQUHAR, DG4 6QP

EPC Report

Energy rating

Current: 55 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 D Current: 55 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 48 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 76 Potential: 76
Field Value
Id 4463023
BUILDING REFERENCE NUMBER 1000042001
OSG REFERENCE NUMBER 137034515
ADDRESS1 43 ANDERSON STREET
ADDRESS2 KELLOHOLM
ADDRESS3 SANQUHAR
POSTCODE DG4 6QP
INSPECTION DATE 2016-06-27
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2016-07-01
ENERGY CONSUMPTION CURRENT 423.00
TOTAL FLOOR AREA 69
3 YR ENERGY COST CURRENT 3450.0000
3 YR ENERGY SAVINGS POTENTIAL 1077.0000
CURRENT ENERGY EFFICIENCY 55
CURRENT ENERGY RATING D
POTENTIAL ENERGY EFFICIENCY 80
POTENTIAL ENERGY RATING C
ENVIRONMENT IMPACT CURRENT 48
CURRENT ENVIRONMENTAL RATING E
ENVIRONMENT IMPACT POTENTIAL 76
POTENTIAL ENVIRONMENTAL RATING C
CO2 EMISS CURR PER FLOOR AREA 75.00
IMPROVEMENTS Description: Floor insulation (solid floor); Indicative Cost: £4,000 - £6,000; Typical Saving: 84; Energy Rating after improvement: D 59; Environmental Rating after improvement: E 53; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £30; Typical Saving: 33; Energy Rating after improvement: D 60; Environmental Rating after improvement: E 54; Green Deal Eligible: N | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 30; Energy Rating after improvement: D 64; Environmental Rating after improvement: D 59; Green Deal Eligible: Y | Description: Hot water cylinder thermostat; Indicative Cost: £200 - £400; Typical Saving: 65; Energy Rating after improvement: D 63; Environmental Rating after improvement: D 57; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 248; Energy Rating after improvement: C 80; Environmental Rating after improvement: C 76; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 77; Energy Rating after improvement: D 67; Environmental Rating after improvement: D 63; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 41; Energy Rating after improvement: D 68; Environmental Rating after improvement: D 66; Green Deal Eligible: Y | Description: Increase loft insulation to 270 mm; Indicative Cost: £100 - £350; Typical Saving: 30; Energy Rating after improvement: D 56; Environmental Rating after improvement: E 49; Green Deal Eligible: Y |
WALL DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALL ENERGY EFF Poor
WALL ENV EFF Poor
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 14% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 5.20
CO2 EMISSIONS POTENTIAL 2.60
HEATING COST CURRENT 2613.0000
HEATING COST POTENTIAL 2013.0000
HOT WATER COST CURRENT 573.00
HOT WATER COST POTENTIAL 219.00
LIGHTING COST CURRENT 264.00
LIGHTING COST POTENTIAL 141.00
ALTERNATIVE IMPROVEMENTS Description: Micro CHP |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 12122
WATER HEATING DEMAND 3108
IMPACT LOFT INSULATION -482
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1930-1949
FLOOR HEIGHT 2.59
DATA ZONE S01001086 (Upper Nithsdale)
ENERGY CONSUMPTION POTENTIAL 207.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 1
LOW ENERGY LIGHTING 14.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL Dumfries and Galloway
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2104
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QHMH
CONSTITUENCY LABEL Mid and Upper Nithsdale
WIND TURBINE COUNT 0
BUILT FORM Semi-Detached
PROPERTY TYPE Bungalow
DATA ZONE 2011 S01007554 (Upper Nithsdale - 03)
CREATED AT 01/07/2016 13:30:03
REPORT REFERENCE NUMBER 1000-1430-0229-1020-1663
Source file Q3 2016.csv
Address display 43 ANDERSON STREET , KELLOHOLM , SANQUHAR
Nation scotland