Energy Performance Certificate
43 ANDERSON STREET , KELLOHOLM , SANQUHAR, DG4 6QP
Energy rating
Current: 55 D | Potential: 80 C
Environmental impact (CO₂)
Current: 48
| Potential: 76
| Field | Value |
|---|---|
| Id | 4463023 |
| BUILDING REFERENCE NUMBER | 1000042001 |
| OSG REFERENCE NUMBER | 137034515 |
| ADDRESS1 | 43 ANDERSON STREET |
| ADDRESS2 | KELLOHOLM |
| ADDRESS3 | SANQUHAR |
| POSTCODE | DG4 6QP |
| INSPECTION DATE | 2016-06-27 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-07-01 |
| ENERGY CONSUMPTION CURRENT | 423.00 |
| TOTAL FLOOR AREA | 69 |
| 3 YR ENERGY COST CURRENT | 3450.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1077.0000 |
| CURRENT ENERGY EFFICIENCY | 55 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 80 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 48 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 76 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 75.00 |
| IMPROVEMENTS | Description: Floor insulation (solid floor); Indicative Cost: £4,000 - £6,000; Typical Saving: 84; Energy Rating after improvement: D 59; Environmental Rating after improvement: E 53; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £30; Typical Saving: 33; Energy Rating after improvement: D 60; Environmental Rating after improvement: E 54; Green Deal Eligible: N | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 30; Energy Rating after improvement: D 64; Environmental Rating after improvement: D 59; Green Deal Eligible: Y | Description: Hot water cylinder thermostat; Indicative Cost: £200 - £400; Typical Saving: 65; Energy Rating after improvement: D 63; Environmental Rating after improvement: D 57; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 248; Energy Rating after improvement: C 80; Environmental Rating after improvement: C 76; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 77; Energy Rating after improvement: D 67; Environmental Rating after improvement: D 63; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 41; Energy Rating after improvement: D 68; Environmental Rating after improvement: D 66; Green Deal Eligible: Y | Description: Increase loft insulation to 270 mm; Indicative Cost: £100 - £350; Typical Saving: 30; Energy Rating after improvement: D 56; Environmental Rating after improvement: E 49; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor |
| WALL ENV EFF | Poor |
| ROOF DESCRIPTION | Pitched, 150 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer and room thermostat |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system, no cylinder thermostat |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Average |
| LIGHTING DESCRIPTION | Low energy lighting in 14% of fixed outlets |
| LIGHTING ENERGY EFF | Poor |
| LIGHTING ENV EFF | Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 5.20 |
| CO2 EMISSIONS POTENTIAL | 2.60 |
| HEATING COST CURRENT | 2613.0000 |
| HEATING COST POTENTIAL | 2013.0000 |
| HOT WATER COST CURRENT | 573.00 |
| HOT WATER COST POTENTIAL | 219.00 |
| LIGHTING COST CURRENT | 264.00 |
| LIGHTING COST POTENTIAL | 141.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Micro CHP | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 12122 |
| WATER HEATING DEMAND | 3108 |
| IMPACT LOFT INSULATION | -482 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1930-1949 |
| FLOOR HEIGHT | 2.59 |
| DATA ZONE | S01001086 (Upper Nithsdale) |
| ENERGY CONSUMPTION POTENTIAL | 207.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 7 |
| LOW ENERGY FIXED LIGHT COUNT | 1 |
| LOW ENERGY LIGHTING | 14.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Dumfries and Galloway |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2104 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QHMH |
| CONSTITUENCY LABEL | Mid and Upper Nithsdale |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | Bungalow |
| DATA ZONE 2011 | S01007554 (Upper Nithsdale - 03) |
| CREATED AT | 01/07/2016 13:30:03 |
| REPORT REFERENCE NUMBER | 1000-1430-0229-1020-1663 |
| Source file | Q3 2016.csv |
| Address display | 43 ANDERSON STREET , KELLOHOLM , SANQUHAR |
| Nation | scotland |