Energy Performance Certificate
New House, Toogs , Bridge End , Burra, ZE2 9LD
Energy rating
Current: 59 D | Potential: 75 C
Environmental impact (CO₂)
Current: 53
| Potential: 69
| Field | Value |
|---|---|
| Id | 4459384 |
| BUILDING REFERENCE NUMBER | 1236573472 |
| OSG REFERENCE NUMBER | — |
| ADDRESS1 | New House, Toogs |
| ADDRESS2 | Bridge End |
| ADDRESS3 | Burra |
| POSTCODE | ZE2 9LD |
| INSPECTION DATE | 2025-04-03 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2025-04-07 |
| ENERGY CONSUMPTION CURRENT | 240.00 |
| TOTAL FLOOR AREA | 251 |
| 3 YR ENERGY COST CURRENT | 11547.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 3375.0000 |
| CURRENT ENERGY EFFICIENCY | 59 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 75 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 53 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 69 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 57.00 |
| IMPROVEMENTS | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 166; Energy Rating after improvement: D 61; Environmental Rating after improvement: D 55; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 892; Energy Rating after improvement: C 69; Environmental Rating after improvement: D 64; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 66; Energy Rating after improvement: C 70; Environmental Rating after improvement: D 65; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 367; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 69; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 250 mm loft insulation | Roof room(s), insulated |
| ROOF ENERGY EFF | Good | Good |
| ROOF ENV EFF | Good | Good |
| FLOOR DESCRIPTION | Suspended, insulated |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Air source heat pump, warm air, electric | Boiler and radiators, oil |
| MAINHEAT ENERGY EFF | Poor | Poor |
| MAINHEAT ENV EFF | Good | Average |
| MAINHEATCONT DESCRIPTION | Programmer and room thermostat | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average | Average |
| MAINHEATC ENV EFF | Average | Average |
| SECONDHEAT DESCRIPTION | Room heaters, dual fuel (mineral and wood) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, standard tariff |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 75% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 14.00 |
| CO2 EMISSIONS POTENTIAL | 4.30 |
| HEATING COST CURRENT | 9180.0000 |
| HEATING COST POTENTIAL | 7122.0000 |
| HOT WATER COST CURRENT | 1707.00 |
| HOT WATER COST POTENTIAL | 390.00 |
| LIGHTING COST CURRENT | 660.00 |
| LIGHTING COST POTENTIAL | 660.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | Description: Air source heat pump | |
| SPACE HEATING DEMAND | 28725 |
| WATER HEATING DEMAND | 2353 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1992-1998 |
| FLOOR HEIGHT | 2.39 |
| DATA ZONE | S01005496 (Central Shetland) |
| ENERGY CONSUMPTION POTENTIAL | 153.00 |
| EXTENSION COUNT | 1 |
| FIXED LIGHTING OUTLETS COUNT | 20 |
| LOW ENERGY FIXED LIGHT COUNT | 15 |
| LOW ENERGY LIGHTING | 75.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 7 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 7 |
| LOCAL AUTHORITY LABEL | Shetland Islands |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | oil (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | non marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00RDMD |
| CONSTITUENCY LABEL | Shetland Central |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Detached |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01012403 (Central Shetland - 02) |
| CREATED AT | 07/04/2025 07:23:26 |
| REPORT REFERENCE NUMBER | 0872-1065-7234-4635-7224 |
| Source file | Q2 2025.csv |
| Address display | New House, Toogs , Bridge End , Burra |
| Nation | scotland |