Energy Performance Certificate

FLAT 12 , 3 GENTLE'S ENTRY , EDINBURGH, EH8 8PD

EPC Report

Energy rating

Current: 78 C | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 C Current: 78 C 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 78 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 Current: 78 78 Potential: 78
Field Value
Id 5124605
BUILDING REFERENCE NUMBER 1000848647
OSG REFERENCE NUMBER 906361417
ADDRESS1 FLAT 12
ADDRESS2 3 GENTLE'S ENTRY
ADDRESS3 EDINBURGH
POSTCODE EH8 8PD
INSPECTION DATE 2024-11-05
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2024-11-12
ENERGY CONSUMPTION CURRENT 157.00
TOTAL FLOOR AREA 73
3 YR ENERGY COST CURRENT 2178.0000
3 YR ENERGY SAVINGS POTENTIAL 0.0000
CURRENT ENERGY EFFICIENCY 78
CURRENT ENERGY RATING C
POTENTIAL ENERGY EFFICIENCY 78
POTENTIAL ENERGY RATING C
ENVIRONMENT IMPACT CURRENT 78
CURRENT ENVIRONMENTAL RATING C
ENVIRONMENT IMPACT POTENTIAL 78
POTENTIAL ENVIRONMENTAL RATING C
CO2 EMISS CURR PER FLOOR AREA 28.00
IMPROVEMENTS
WALL DESCRIPTION System built, as built, insulated (assumed)
WALL ENERGY EFF Good
WALL ENV EFF Good
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 2.00
CO2 EMISSIONS POTENTIAL 0.00
HEATING COST CURRENT 1524.0000
HEATING COST POTENTIAL 1524.0000
HOT WATER COST CURRENT 387.00
HOT WATER COST POTENTIAL 387.00
LIGHTING COST CURRENT 267.00
LIGHTING COST POTENTIAL 267.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 5349
WATER HEATING DEMAND 1910
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1999-2002
FLOOR HEIGHT 2.27
DATA ZONE S01002101 (Southside and Canongate)
ENERGY CONSUMPTION POTENTIAL 157.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL top floor
FLAT TOP STOREY 06
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL Edinburgh City
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH 9.57
CONSTITUENCY 00QPML
CONSTITUENCY LABEL City Centre
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01008684 (Canongate, Southside and Dumbiedykes - 05)
CREATED AT 12/11/2024 11:21:13
REPORT REFERENCE NUMBER 0857-1908-4209-6784-4200
Source file Q4 2024.csv
Address display FLAT 12 , 3 GENTLE'S ENTRY , EDINBURGH
Nation scotland