Energy Performance Certificate
35 LOCHNELL ROAD , DUNBEG , OBAN, PA37 1QJ
Energy rating
Current: 69 C | Potential: 92 A
Environmental impact (CO₂)
Current: 49
| Potential: 76
| Field | Value |
|---|---|
| Id | 3802834 |
| BUILDING REFERENCE NUMBER | 1001075970 |
| OSG REFERENCE NUMBER | 125004448 |
| ADDRESS1 | 35 LOCHNELL ROAD |
| ADDRESS2 | DUNBEG |
| ADDRESS3 | OBAN |
| POSTCODE | PA37 1QJ |
| INSPECTION DATE | 2020-02-05 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2020-02-10 |
| ENERGY CONSUMPTION CURRENT | 510.00 |
| TOTAL FLOOR AREA | 50 |
| 3 YR ENERGY COST CURRENT | 2490.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 642.0000 |
| CURRENT ENERGY EFFICIENCY | 69 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 92 |
| POTENTIAL ENERGY RATING | A |
| ENVIRONMENT IMPACT CURRENT | 49 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 76 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 86.00 |
| IMPROVEMENTS | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 66; Energy Rating after improvement: C 77; Environmental Rating after improvement: D 63; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 290; Energy Rating after improvement: A 92; Environmental Rating after improvement: C 76; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 148; Energy Rating after improvement: C 74; Environmental Rating after improvement: D 57; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, with external insulation |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 200 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | Controls for high heat retention storage heaters |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Portable electric heaters (assumed) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.30 |
| CO2 EMISSIONS POTENTIAL | 2.00 |
| HEATING COST CURRENT | 1836.0000 |
| HEATING COST POTENTIAL | 1419.0000 |
| HOT WATER COST CURRENT | 513.00 |
| HOT WATER COST POTENTIAL | 288.00 |
| LIGHTING COST CURRENT | 141.00 |
| LIGHTING COST POTENTIAL | 141.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 6218 |
| WATER HEATING DEMAND | 1803 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1965-1975 |
| FLOOR HEIGHT | 2.3 |
| DATA ZONE | S01000826 (Benderloch Trail) |
| ENERGY CONSUMPTION POTENTIAL | 272.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 6 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | Argyll and Bute |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric storage heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2404 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QDME |
| CONSTITUENCY LABEL | Oban North and Lorn |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01007302 (Benderloch Trail - 02) |
| CREATED AT | 10/02/2020 13:59:15 |
| REPORT REFERENCE NUMBER | 0850-1010-7202-9450-7204 |
| Source file | Q1 2020.csv |
| Address display | 35 LOCHNELL ROAD , DUNBEG , OBAN |
| Nation | scotland |