Energy Performance Certificate
52 MANSE VIEW , NEWARTHILL , MOTHERWELL, ML1 5TB
Energy rating
Current: 53 E | Potential: 80 C
Environmental impact (CO₂)
Current: 57
| Potential: 68
| Field | Value |
|---|---|
| Id | 4984546 |
| BUILDING REFERENCE NUMBER | 1000801157 |
| OSG REFERENCE NUMBER | 118004991 |
| ADDRESS1 | 52 MANSE VIEW |
| ADDRESS2 | NEWARTHILL |
| ADDRESS3 | MOTHERWELL |
| POSTCODE | ML1 5TB |
| INSPECTION DATE | 2020-12-08 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2020-12-10 |
| ENERGY CONSUMPTION CURRENT | 447.00 |
| TOTAL FLOOR AREA | 35 |
| 3 YR ENERGY COST CURRENT | 2850.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1683.0000 |
| CURRENT ENERGY EFFICIENCY | 53 |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY EFFICIENCY | 80 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 57 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 68 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 75.00 |
| IMPROVEMENTS | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 82; Energy Rating after improvement: D 57; Environmental Rating after improvement: D 61; Green Deal Eligible: Y | ; Indicative Cost: £300 - £600; Typical Saving: 100; Energy Rating after improvement: D 62; Environmental Rating after improvement: D 65; Green Deal Eligible: Y | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 28; Energy Rating after improvement: D 63; Environmental Rating after improvement: D 67; Green Deal Eligible: Y | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £800 - £1,200; Typical Saving: 318; Energy Rating after improvement: C 79; Environmental Rating after improvement: D 65; Green Deal Eligible: Y | Description: Replacement glazing units; Indicative Cost: £1,000 - £1,400; Typical Saving: 35; Energy Rating after improvement: C 80; Environmental Rating after improvement: D 68; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, partial insulation (assumed) |
| WALL ENERGY EFF | Average |
| WALL ENV EFF | Average |
| ROOF DESCRIPTION | Pitched, 200 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Room heaters, electric |
| MAINHEAT ENERGY EFF | Very Poor |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | Programmer and appliance thermostats |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, standard tariff |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 67% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.60 |
| CO2 EMISSIONS POTENTIAL | 0.60 |
| HEATING COST CURRENT | 1785.0000 |
| HEATING COST POTENTIAL | 582.0000 |
| HOT WATER COST CURRENT | 933.00 |
| HOT WATER COST POTENTIAL | 438.00 |
| LIGHTING COST CURRENT | 132.00 |
| LIGHTING COST POTENTIAL | 147.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 3181 |
| WATER HEATING DEMAND | 1664 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | -436 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1976-1983 |
| FLOOR HEIGHT | 2.33 |
| DATA ZONE | S01004658 (Newarthill) |
| ENERGY CONSUMPTION POTENTIAL | 336.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 4 |
| LOW ENERGY LIGHTING | 67.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 01 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | no corridor |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | North Lanarkshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | room heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2603 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QZMS |
| CONSTITUENCY LABEL | Motherwell North |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01011452 (Newarthill - 01) |
| CREATED AT | 10/12/2020 21:35:19 |
| REPORT REFERENCE NUMBER | 0787-1908-5202-1310-0200 |
| Source file | Q4 2020.csv |
| Address display | 52 MANSE VIEW , NEWARTHILL , MOTHERWELL |
| Nation | scotland |