Energy Performance Certificate
56 BAY STREET , FAIRLIE , LARGS, KA29 0AL
Energy rating
Current: 72 C | Potential: 85 B
Environmental impact (CO₂)
Current: 71
| Potential: 83
| Field | Value |
|---|---|
| Id | 4320141 |
| BUILDING REFERENCE NUMBER | 1000276237 |
| OSG REFERENCE NUMBER | 126065721 |
| ADDRESS1 | 56 BAY STREET |
| ADDRESS2 | FAIRLIE |
| ADDRESS3 | LARGS |
| POSTCODE | KA29 0AL |
| INSPECTION DATE | 2023-06-05 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2023-06-05 |
| ENERGY CONSUMPTION CURRENT | 236.00 |
| TOTAL FLOOR AREA | 77 |
| 3 YR ENERGY COST CURRENT | 4908.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 327.0000 |
| CURRENT ENERGY EFFICIENCY | 72 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 85 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 71 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 83 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 42.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £15; Typical Saving: 38; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 71; Green Deal Eligible: N | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 71; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 73; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 628; Energy Rating after improvement: B 85; Environmental Rating after improvement: B 83; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, insulated (assumed) | Roof room(s), insulated (assumed) |
| ROOF ENERGY EFF | Good | Good |
| ROOF ENV EFF | Good | Good |
| FLOOR DESCRIPTION | Suspended, insulated (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 67% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 3.20 |
| CO2 EMISSIONS POTENTIAL | 1.10 |
| HEATING COST CURRENT | 3771.0000 |
| HEATING COST POTENTIAL | 3792.0000 |
| HOT WATER COST CURRENT | 603.00 |
| HOT WATER COST POTENTIAL | 390.00 |
| LIGHTING COST CURRENT | 534.00 |
| LIGHTING COST POTENTIAL | 399.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 9558 |
| WATER HEATING DEMAND | 1843 |
| IMPACT LOFT INSULATION | -127 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1999-2002 |
| FLOOR HEIGHT | 2.34 |
| DATA ZONE | S01004507 (Fairlie and Rural) |
| ENERGY CONSUMPTION POTENTIAL | 152.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 9 |
| LOW ENERGY FIXED LIGHT COUNT | 6 |
| LOW ENERGY LIGHTING | 67.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | North Ayrshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QYMH |
| CONSTITUENCY LABEL | North Coast and Cumbraes |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Detached |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01011310 (Fairlie and Rural - 04) |
| CREATED AT | 05/06/2023 21:12:56 |
| REPORT REFERENCE NUMBER | 0657-1002-3206-2467-7204 |
| Source file | Q2 2023.csv |
| Address display | 56 BAY STREET , FAIRLIE , LARGS |
| Nation | scotland |