Energy Performance Certificate
FLAT 3/2 , 19 WOODLANDS DRIVE , GLASGOW, G4 9DN
Energy rating
Current: 12 G | Potential: 76 C
Environmental impact (CO₂)
Current: 1
| Potential: 60
| Field | Value |
|---|---|
| Id | 4866228 |
| BUILDING REFERENCE NUMBER | 1000826720 |
| OSG REFERENCE NUMBER | 906700118826 |
| ADDRESS1 | FLAT 3/2 |
| ADDRESS2 | 19 WOODLANDS DRIVE |
| ADDRESS3 | GLASGOW |
| POSTCODE | G4 9DN |
| INSPECTION DATE | 2016-12-02 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-12-03 |
| ENERGY CONSUMPTION CURRENT | 907.00 |
| TOTAL FLOOR AREA | 209 |
| 3 YR ENERGY COST CURRENT | 16767.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 12972.0000 |
| CURRENT ENERGY EFFICIENCY | 12 |
| CURRENT ENERGY RATING | G |
| POTENTIAL ENERGY EFFICIENCY | 76 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 1 |
| CURRENT ENVIRONMENTAL RATING | G |
| ENVIRONMENT IMPACT POTENTIAL | 60 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 153.00 |
| IMPROVEMENTS | Description: Increase loft insulation to 270 mm; Indicative Cost: £100 - £350; Typical Saving: 2221; Energy Rating after improvement: F 38; Environmental Rating after improvement: F 24; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 1200; Energy Rating after improvement: D 59; Environmental Rating after improvement: E 44; Green Deal Eligible: Y | Description: Increase hot water cylinder insulation; Indicative Cost: £15 - £30; Typical Saving: 67; Energy Rating after improvement: D 61; Environmental Rating after improvement: E 45; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £55; Typical Saving: 79; Energy Rating after improvement: D 64; Environmental Rating after improvement: E 47; Green Deal Eligible: N | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £1,600 - £2,400; Typical Saving: 472; Energy Rating after improvement: C 73; Environmental Rating after improvement: E 53; Green Deal Eligible: Y | Description: Replace single glazed windows with low-E double glazed windows; Indicative Cost: £3,300 - £6,500; Typical Saving: 206; Energy Rating after improvement: C 76; Environmental Rating after improvement: D 60; Green Deal Eligible: Y | Description: Draughtproofing; Indicative Cost: £80 - £120; Typical Saving: 80; Energy Rating after improvement: D 62; Environmental Rating after improvement: E 47; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) |
| WALL ENERGY EFF | Very Poor |
| WALL ENV EFF | Very Poor |
| ROOF DESCRIPTION | Pitched, no insulation |
| ROOF ENERGY EFF | Very Poor |
| ROOF ENV EFF | Very Poor |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Single glazed |
| WINDOWS ENERGY EFF | Very Poor |
| WINDOWS ENV EFF | Very Poor |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Manual charge control |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Portable electric heaters (assumed) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 32.00 |
| CO2 EMISSIONS POTENTIAL | 24.20 |
| HEATING COST CURRENT | 14826.0000 |
| HEATING COST POTENTIAL | 2928.0000 |
| HOT WATER COST CURRENT | 1260.00 |
| HOT WATER COST POTENTIAL | 519.00 |
| LIGHTING COST CURRENT | 681.00 |
| LIGHTING COST POTENTIAL | 348.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 57247 |
| WATER HEATING DEMAND | 3030 |
| IMPACT LOFT INSULATION | -25762 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -13926 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 3.19 |
| DATA ZONE | S01003474 (Woodlands) |
| ENERGY CONSUMPTION POTENTIAL | 221.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 11 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 03 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Glasgow City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric storage heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2401 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | not defined |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | ECO assessment |
| UNHEATED CORRIDOR LENGTH | 8 |
| CONSTITUENCY | 00QSML |
| CONSTITUENCY LABEL | Hillhead |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01010294 (Woodlands - 06) |
| CREATED AT | 03/12/2016 00:55:14 |
| REPORT REFERENCE NUMBER | 0620-1908-2202-7166-2900 |
| Source file | Q4 2016.csv |
| Address display | FLAT 3/2 , 19 WOODLANDS DRIVE , GLASGOW |
| Nation | scotland |