Energy Performance Certificate
39 BAILIE NORRIE CRESCENT , MONTROSE, DD10 9DT
Energy rating
Current: 74 C | Potential: 83 B
Environmental impact (CO₂)
Current: 70
| Potential: 79
| Field | Value |
|---|---|
| Id | 4094264 |
| BUILDING REFERENCE NUMBER | 1000597440 |
| OSG REFERENCE NUMBER | 117073661 |
| ADDRESS1 | 39 BAILIE NORRIE CRESCENT |
| ADDRESS2 | — |
| ADDRESS3 | MONTROSE |
| POSTCODE | DD10 9DT |
| INSPECTION DATE | 2016-06-28 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-29 |
| ENERGY CONSUMPTION CURRENT | 195.00 |
| TOTAL FLOOR AREA | 129 |
| 3 YR ENERGY COST CURRENT | 3084.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 216.0000 |
| CURRENT ENERGY EFFICIENCY | 74 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 83 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 70 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 79 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 34.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £30; Typical Saving: 27; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 72; Green Deal Eligible: N | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 267; Energy Rating after improvement: B 83; Environmental Rating after improvement: C 79; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 45; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | |
| WALL DESCRIPTION | System built, as built, partial insulation (assumed) |
| WALL ENERGY EFF | Average |
| WALL ENV EFF | Average |
| ROOF DESCRIPTION | Pitched, 150 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 57% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.50 |
| CO2 EMISSIONS POTENTIAL | 1.30 |
| HEATING COST CURRENT | 2466.0000 |
| HEATING COST POTENTIAL | 2346.0000 |
| HOT WATER COST CURRENT | 300.00 |
| HOT WATER COST POTENTIAL | 300.00 |
| LIGHTING COST CURRENT | 318.00 |
| LIGHTING COST POTENTIAL | 222.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 14728 |
| WATER HEATING DEMAND | 2072 |
| IMPACT LOFT INSULATION | -319 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1976-1983 |
| FLOOR HEIGHT | 2.4 |
| DATA ZONE | S01000690 (Montrose North) |
| ENERGY CONSUMPTION POTENTIAL | 140.00 |
| EXTENSION COUNT | 1 |
| FIXED LIGHTING OUTLETS COUNT | 14 |
| LOW ENERGY FIXED LIGHT COUNT | 8 |
| LOW ENERGY LIGHTING | 57.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 7 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 7 |
| LOCAL AUTHORITY LABEL | Angus |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QCMH |
| CONSTITUENCY LABEL | Montrose and District |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01007218 (Montrose North - 04) |
| CREATED AT | 29/06/2016 13:57:12 |
| REPORT REFERENCE NUMBER | 0500-3984-0729-7024-1663 |
| Source file | Q2 2016.csv |
| Address display | 39 BAILIE NORRIE CRESCENT , MONTROSE |
| Nation | scotland |