Energy Performance Certificate
8 JOHNSTON STREET , WHINS OF MILTON , STIRLING, FK7 0NA
Energy rating
Current: 58 D | Potential: 74 C
Environmental impact (CO₂)
Current: 51
| Potential: 67
| Field | Value |
|---|---|
| Id | 4865391 |
| BUILDING REFERENCE NUMBER | 1000836834 |
| OSG REFERENCE NUMBER | 122025919 |
| ADDRESS1 | 8 JOHNSTON STREET |
| ADDRESS2 | WHINS OF MILTON |
| ADDRESS3 | STIRLING |
| POSTCODE | FK7 0NA |
| INSPECTION DATE | 2016-12-06 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-12-08 |
| ENERGY CONSUMPTION CURRENT | 328.00 |
| TOTAL FLOOR AREA | 86 |
| 3 YR ENERGY COST CURRENT | 3363.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 441.0000 |
| CURRENT ENERGY EFFICIENCY | 58 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 74 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 51 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 67 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 58.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £25; Typical Saving: 18; Energy Rating after improvement: D 61; Environmental Rating after improvement: D 55; Green Deal Eligible: N | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 34; Energy Rating after improvement: D 63; Environmental Rating after improvement: D 56; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 246; Energy Rating after improvement: C 74; Environmental Rating after improvement: D 67; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 63; Energy Rating after improvement: D 61; Environmental Rating after improvement: E 54; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 32; Energy Rating after improvement: D 64; Environmental Rating after improvement: D 58; Green Deal Eligible: Y | |
| WALL DESCRIPTION | System built, with external insulation |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, no insulation (assumed) |
| ROOF ENERGY EFF | Very Poor |
| ROOF ENV EFF | Very Poor |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully triple glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 62% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 5.00 |
| CO2 EMISSIONS POTENTIAL | 1.50 |
| HEATING COST CURRENT | 2841.0000 |
| HEATING COST POTENTIAL | 2562.0000 |
| HOT WATER COST CURRENT | 279.00 |
| HOT WATER COST POTENTIAL | 186.00 |
| LIGHTING COST CURRENT | 243.00 |
| LIGHTING COST POTENTIAL | 174.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 12420 |
| WATER HEATING DEMAND | 1946 |
| IMPACT LOFT INSULATION | -4369 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | 2.44 |
| DATA ZONE | S01006090 (Bannockburn) |
| ENERGY CONSUMPTION POTENTIAL | 225.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 13 |
| LOW ENERGY FIXED LIGHT COUNT | 8 |
| LOW ENERGY LIGHTING | 62.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Stirling |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | triple glazing |
| NUMBER OPEN FIREPLACES | 1 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | ECO assessment |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00RGMF |
| CONSTITUENCY LABEL | Stirling East |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | End-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01013043 (Hillpark - 02) |
| CREATED AT | 08/12/2016 17:13:42 |
| REPORT REFERENCE NUMBER | 0464-1908-3202-8366-3904 |
| Source file | Q4 2016.csv |
| Address display | 8 JOHNSTON STREET , WHINS OF MILTON , STIRLING |
| Nation | scotland |