Energy Performance Certificate
KILGRANGE , DALCHREICHART , INVERNESS, IV63 7YJ
Energy rating
Current: 58 D | Potential: 101 A
Environmental impact (CO₂)
Current: 50
| Potential: 91
| Field | Value |
|---|---|
| Id | 4092570 |
| BUILDING REFERENCE NUMBER | 1000445180 |
| OSG REFERENCE NUMBER | 130099167 |
| ADDRESS1 | KILGRANGE |
| ADDRESS2 | DALCHREICHART |
| ADDRESS3 | INVERNESS |
| POSTCODE | IV63 7YJ |
| INSPECTION DATE | 2016-06-10 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-14 |
| ENERGY CONSUMPTION CURRENT | 306.00 |
| TOTAL FLOOR AREA | 85 |
| 3 YR ENERGY COST CURRENT | 3588.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 873.0000 |
| CURRENT ENERGY EFFICIENCY | 58 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 101 |
| POTENTIAL ENERGY RATING | A |
| ENVIRONMENT IMPACT CURRENT | 50 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 91 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 78.00 |
| IMPROVEMENTS | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 93; Energy Rating after improvement: D 64; Environmental Rating after improvement: D 57; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 43; Energy Rating after improvement: C 69; Environmental Rating after improvement: D 63; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 226; Energy Rating after improvement: C 80; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | Description: Wind turbine; Indicative Cost: £15,000 - £25,000; Typical Saving: 548; Energy Rating after improvement: A 101; Environmental Rating after improvement: B 91; Green Deal Eligible: Y | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 50; Energy Rating after improvement: D 67; Environmental Rating after improvement: D 60; Green Deal Eligible: Y | Description: Increase loft insulation to 270 mm; Indicative Cost: £100 - £350; Typical Saving: 75; Energy Rating after improvement: D 61; Environmental Rating after improvement: E 53; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £20; Typical Saving: 30; Energy Rating after improvement: D 65; Environmental Rating after improvement: D 58; Green Deal Eligible: N | |
| WALL DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 100 mm loft insulation |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| FLOOR DESCRIPTION | Suspended, limited insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, oil |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Average |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | Room heaters, dual fuel (mineral and wood) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Average |
| LIGHTING DESCRIPTION | Low energy lighting in 33% of fixed outlets |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 6.60 |
| CO2 EMISSIONS POTENTIAL | 4.20 |
| HEATING COST CURRENT | 2901.0000 |
| HEATING COST POTENTIAL | 2271.0000 |
| HOT WATER COST CURRENT | 402.00 |
| HOT WATER COST POTENTIAL | 273.00 |
| LIGHTING COST CURRENT | 285.00 |
| LIGHTING COST POTENTIAL | 171.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 14349 |
| WATER HEATING DEMAND | 2148 |
| IMPACT LOFT INSULATION | -1162 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1992-1998 |
| FLOOR HEIGHT | 2.37 |
| DATA ZONE | S01003753 (Loch Ness) |
| ENERGY CONSUMPTION POTENTIAL | 49.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 2 |
| LOW ENERGY LIGHTING | 33.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Highland |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | oil (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QTMN |
| CONSTITUENCY LABEL | Aird and Loch Ness |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Detached |
| PROPERTY TYPE | Bungalow |
| DATA ZONE 2011 | S01010668 (Loch Ness - 05) |
| CREATED AT | 14/06/2016 08:41:19 |
| REPORT REFERENCE NUMBER | 0400-7401-0529-4098-1663 |
| Source file | Q2 2016.csv |
| Address display | KILGRANGE , DALCHREICHART , INVERNESS |
| Nation | scotland |