Energy Performance Certificate
FLAT 2 , 6 BURNS STREET , EDINBURGH, EH6 8DS
Energy rating
Current: 74 C | Potential: 79 C
Environmental impact (CO₂)
Current: 72
| Potential: 79
| Field | Value |
|---|---|
| Id | 4001214 |
| BUILDING REFERENCE NUMBER | 1000708972 |
| OSG REFERENCE NUMBER | 906343582 |
| ADDRESS1 | FLAT 2 |
| ADDRESS2 | 6 BURNS STREET |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH6 8DS |
| INSPECTION DATE | 2025-03-04 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2025-03-12 |
| ENERGY CONSUMPTION CURRENT | 193.00 |
| TOTAL FLOOR AREA | 73 |
| 3 YR ENERGY COST CURRENT | 2454.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 495.0000 |
| CURRENT ENERGY EFFICIENCY | 74 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 79 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 72 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 79 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 34.00 |
| IMPROVEMENTS | Description: Floor insulation (solid floor); Indicative Cost: £4,000 - £6,000; Typical Saving: 88; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 78; Green Deal Eligible: Y | Description: Replacement glazing units; Indicative Cost: £1,000 - £1,400; Typical Saving: 42; Energy Rating after improvement: C 79; Environmental Rating after improvement: C 79; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 35; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 74; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, partial insulation (assumed) | Cavity wall, filled cavity |
| WALL ENERGY EFF | Average | Average |
| WALL ENV EFF | Average | Average |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.50 |
| CO2 EMISSIONS POTENTIAL | 0.60 |
| HEATING COST CURRENT | 1644.0000 |
| HEATING COST POTENTIAL | 1143.0000 |
| HOT WATER COST CURRENT | 567.00 |
| HOT WATER COST POTENTIAL | 573.00 |
| LIGHTING COST CURRENT | 243.00 |
| LIGHTING COST POTENTIAL | 243.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 6094 |
| WATER HEATING DEMAND | 2605 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | -512 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1965-1975 |
| FLOOR HEIGHT | 2.35 |
| DATA ZONE | S01002273 (South Leith) |
| ENERGY CONSUMPTION POTENTIAL | 145.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 8 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | ground floor |
| FLAT TOP STOREY | 00 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | none of the above |
| UNHEATED CORRIDOR LENGTH | 11.8 |
| CONSTITUENCY | 00QPMN |
| CONSTITUENCY LABEL | Leith |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01008792 (South Leith - 01) |
| CREATED AT | 12/03/2025 13:45:15 |
| REPORT REFERENCE NUMBER | 0342-1007-7207-9685-0200 |
| Source file | Q1 2025.csv |
| Address display | FLAT 2 , 6 BURNS STREET , EDINBURGH |
| Nation | scotland |