Energy Performance Certificate
1F2 , 4 EDINA STREET , EDINBURGH, EH7 5PN
Energy rating
Current: 74 C | Potential: 82 B
Environmental impact (CO₂)
Current: 76
| Potential: 86
| Field | Value |
|---|---|
| Id | 4716652 |
| BUILDING REFERENCE NUMBER | 1000242921 |
| OSG REFERENCE NUMBER | 906352626 |
| ADDRESS1 | 1F2 |
| ADDRESS2 | 4 EDINA STREET |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH7 5PN |
| INSPECTION DATE | 2023-09-07 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2023-09-18 |
| ENERGY CONSUMPTION CURRENT | 206.00 |
| TOTAL FLOOR AREA | 49 |
| 3 YR ENERGY COST CURRENT | 2952.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1074.0000 |
| CURRENT ENERGY EFFICIENCY | 74 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 82 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 76 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 86 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 36.00 |
| IMPROVEMENTS | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 202; Energy Rating after improvement: C 78; Environmental Rating after improvement: B 82; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 95; Energy Rating after improvement: C 80; Environmental Rating after improvement: B 85; Green Deal Eligible: Y | Description: Replacement glazing units; Indicative Cost: £1,000 - £1,400; Typical Saving: 60; Energy Rating after improvement: B 82; Environmental Rating after improvement: B 86; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor | Poor |
| WALL ENV EFF | Poor | Poor |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 1.80 |
| CO2 EMISSIONS POTENTIAL | 0.80 |
| HEATING COST CURRENT | 1959.0000 |
| HEATING COST POTENTIAL | 1008.0000 |
| HOT WATER COST CURRENT | 741.00 |
| HOT WATER COST POTENTIAL | 618.00 |
| LIGHTING COST CURRENT | 252.00 |
| LIGHTING COST POTENTIAL | 252.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 3539 |
| WATER HEATING DEMAND | 1677 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -1485 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 3.06 |
| DATA ZONE | S01002198 (Hillside and Calton Hill) |
| ENERGY CONSUMPTION POTENTIAL | 118.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 12 |
| LOW ENERGY FIXED LIGHT COUNT | 12 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | mid floor |
| FLAT TOP STOREY | 01 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | 4.31 |
| CONSTITUENCY | 00QPMM |
| CONSTITUENCY LABEL | Leith Walk |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01008807 (Hillside and Calton Hill - 02) |
| CREATED AT | 18/09/2023 11:26:33 |
| REPORT REFERENCE NUMBER | 0331-1002-2201-9727-4204 |
| Source file | Q3 2023.csv |
| Address display | 1F2 , 4 EDINA STREET , EDINBURGH |
| Nation | scotland |