Energy Performance Certificate
11 MILLBURN PARK , LAUDER, TD2 6SL
Energy rating
Current: 76 C | Potential: 81 B
Environmental impact (CO₂)
Current: 69
| Potential: 75
| Field | Value |
|---|---|
| Id | 4438096 |
| BUILDING REFERENCE NUMBER | 1001774080 |
| OSG REFERENCE NUMBER | 116021844 |
| ADDRESS1 | 11 MILLBURN PARK |
| ADDRESS2 | — |
| ADDRESS3 | LAUDER |
| POSTCODE | TD2 6SL |
| INSPECTION DATE | 2025-05-08 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2025-06-27 |
| ENERGY CONSUMPTION CURRENT | 231.00 |
| TOTAL FLOOR AREA | 101 |
| 3 YR ENERGY COST CURRENT | 5124.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 756.0000 |
| CURRENT ENERGY EFFICIENCY | 76 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 81 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 69 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 75 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 41.00 |
| IMPROVEMENTS | Description: Floor insulation (suspended floor); Indicative Cost: £5,000 - £10,000; Typical Saving: 98; Energy Rating after improvement: C 80; Environmental Rating after improvement: C 75; Green Deal Eligible: N | Description: Solar water heating; Indicative Cost: £4,000 - £7,000; Typical Saving: 52; Energy Rating after improvement: B 81; Environmental Rating after improvement: C 75; Green Deal Eligible: N | Description: Cavity wall insulation; Indicative Cost: £900 - £1,500; Typical Saving: 96; Energy Rating after improvement: C 78; Environmental Rating after improvement: C 72; Green Deal Eligible: N | |
| WALL DESCRIPTION | Cavity wall, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor |
| WALL ENV EFF | Poor |
| ROOF DESCRIPTION | Pitched, 300 mm loft insulation | Roof room(s), no insulation (assumed) |
| ROOF ENERGY EFF | Very Good | Very Poor |
| ROOF ENV EFF | Very Good | Very Poor |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | — |
| WINDOWS ENERGY EFF | — |
| WINDOWS ENV EFF | — |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric instantaneous at point of use |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Below average lighting efficiency |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.20 |
| CO2 EMISSIONS POTENTIAL | 0.80 |
| HEATING COST CURRENT | 3798.0000 |
| HEATING COST POTENTIAL | 3216.0000 |
| HOT WATER COST CURRENT | 1095.00 |
| HOT WATER COST POTENTIAL | 921.00 |
| LIGHTING COST CURRENT | 231.00 |
| LIGHTING COST POTENTIAL | 231.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | |
| LZC ENERGY SOURCES | Description: Solar photovoltaics | |
| SPACE HEATING DEMAND | 17707.36 |
| WATER HEATING DEMAND | 1401.67 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | — |
| DATA ZONE | S01005465 (Earlston, Lauder and Stow area) |
| ENERGY CONSUMPTION POTENTIAL | 190.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 0 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 0 |
| NUMBER HABITABLE ROOMS | 5 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 5 |
| LOCAL AUTHORITY LABEL | Scottish Borders |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | — |
| MAIN FUEL | — |
| MAIN HEATING CONTROLS | — |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | — |
| NUMBER OPEN FIREPLACES | — |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | ECO assessment |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QEME |
| CONSTITUENCY LABEL | Leaderdale and Melrose |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01012296 (Lauder - South) |
| CREATED AT | 27/06/2025 12:40:07 |
| REPORT REFERENCE NUMBER | 0280-1017-8205-0845-7204 |
| Source file | Q2 2025.csv |
| Address display | 11 MILLBURN PARK , LAUDER |
| Nation | scotland |