Energy Performance Certificate
24 OLD STATION PLACE , BALLATER, AB35 5RG
Energy rating
Current: 89 B | Potential: 98 A
Environmental impact (CO₂)
Current: 67
| Potential: 81
| Field | Value |
|---|---|
| Id | 3805732 |
| BUILDING REFERENCE NUMBER | 1001214420 |
| OSG REFERENCE NUMBER | 151036410 |
| ADDRESS1 | 24 OLD STATION PLACE |
| ADDRESS2 | — |
| ADDRESS3 | BALLATER |
| POSTCODE | AB35 5RG |
| INSPECTION DATE | 2019-01-07 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2020-01-12 |
| ENERGY CONSUMPTION CURRENT | 473.00 |
| TOTAL FLOOR AREA | 50 |
| 3 YR ENERGY COST CURRENT | 2994.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 813.0000 |
| CURRENT ENERGY EFFICIENCY | 89 |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY EFFICIENCY | 98 |
| POTENTIAL ENERGY RATING | A |
| ENVIRONMENT IMPACT CURRENT | 67 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 81 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 80.00 |
| IMPROVEMENTS | Description: High heat retention storage heaters; Indicative Cost: £800 - £1,200; Typical Saving: 175; Energy Rating after improvement: A 94; Environmental Rating after improvement: C 74; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 62; Energy Rating after improvement: A 97; Environmental Rating after improvement: C 79; Green Deal Eligible: Y | Description: High performance external doors; Indicative Cost: £1,000; Typical Saving: 34; Energy Rating after improvement: A 98; Environmental Rating after improvement: B 81; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 300 mm loft insulation |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| FLOOR DESCRIPTION | Suspended, insulated |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Manual charge control |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.00 |
| CO2 EMISSIONS POTENTIAL | 1.20 |
| HEATING COST CURRENT | 2403.0000 |
| HEATING COST POTENTIAL | 1782.0000 |
| HOT WATER COST CURRENT | 459.00 |
| HOT WATER COST POTENTIAL | 267.00 |
| LIGHTING COST CURRENT | 132.00 |
| LIGHTING COST POTENTIAL | 132.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | Description: Solar photovoltaics | |
| SPACE HEATING DEMAND | 8198 |
| WATER HEATING DEMAND | 1612 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1976-1983 |
| FLOOR HEIGHT | 2.23 |
| DATA ZONE | S01000316 (East Cairngorms) |
| ENERGY CONSUMPTION POTENTIAL | 323.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 8 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | Aberdeenshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric storage heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2401 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Peak Power: 3.15; Orientation: South East; Pitch: 30 degrees; Overshading: none or very little; Connection: connected to dwelling’s electricity meter; | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QBMQ |
| CONSTITUENCY LABEL | Aboyne, Upper Deeside and Donside |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | Bungalow |
| DATA ZONE 2011 | S01006790 (East Cairngorms - 02) |
| CREATED AT | 12/01/2020 21:10:58 |
| REPORT REFERENCE NUMBER | 0230-1012-2209-4841-1900 |
| Source file | Q1 2020.csv |
| Address display | 24 OLD STATION PLACE , BALLATER |
| Nation | scotland |