Energy Performance Certificate
93 WINIFRED CRESCENT , KIRKCALDY, KY2 5SY
Energy rating
Current: 58 D | Potential: 81 B
Environmental impact (CO₂)
Current: 55
| Potential: 80
| Field | Value |
|---|---|
| Id | 4100663 |
| BUILDING REFERENCE NUMBER | 1001212320 |
| OSG REFERENCE NUMBER | 320007680 |
| ADDRESS1 | 93 WINIFRED CRESCENT |
| ADDRESS2 | — |
| ADDRESS3 | KIRKCALDY |
| POSTCODE | KY2 5SY |
| INSPECTION DATE | 2016-06-14 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-16 |
| ENERGY CONSUMPTION CURRENT | 324.00 |
| TOTAL FLOOR AREA | 89 |
| 3 YR ENERGY COST CURRENT | 3672.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1140.0000 |
| CURRENT ENERGY EFFICIENCY | 58 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 81 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 55 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 80 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 57.00 |
| IMPROVEMENTS | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 36; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 71; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 233; Energy Rating after improvement: D 66; Environmental Rating after improvement: D 65; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 64; Energy Rating after improvement: D 68; Environmental Rating after improvement: D 68; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £40; Typical Saving: 48; Energy Rating after improvement: C 70; Environmental Rating after improvement: C 69; Green Deal Eligible: N | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 260; Energy Rating after improvement: B 81; Environmental Rating after improvement: C 80; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor |
| WALL ENV EFF | Poor |
| ROOF DESCRIPTION | Pitched, 100 mm loft insulation |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 5.10 |
| CO2 EMISSIONS POTENTIAL | 2.60 |
| HEATING COST CURRENT | 2994.0000 |
| HEATING COST POTENTIAL | 2133.0000 |
| HOT WATER COST CURRENT | 330.00 |
| HOT WATER COST POTENTIAL | 225.00 |
| LIGHTING COST CURRENT | 348.00 |
| LIGHTING COST POTENTIAL | 174.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 14981 |
| WATER HEATING DEMAND | 2194 |
| IMPACT LOFT INSULATION | -466 |
| IMPACT CAVITY WALL INSULATION | -4024 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | 2.4 |
| DATA ZONE | S01002742 (Kirkcaldy Bennochy West) |
| ENERGY CONSUMPTION POTENTIAL | 156.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Fife |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | none of the above |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QRMM |
| CONSTITUENCY LABEL | Kirkcaldy Central |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | End-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01009487 (Forth Park North) |
| CREATED AT | 16/06/2016 13:49:19 |
| REPORT REFERENCE NUMBER | 0200-0143-0229-4192-1663 |
| Source file | Q2 2016.csv |
| Address display | 93 WINIFRED CRESCENT , KIRKCALDY |
| Nation | scotland |