Energy Performance Certificate
8 PINEFIELD , CARRBRIDGE, PH23 3BL
Energy rating
Current: 80 C | Potential: 94 A
Environmental impact (CO₂)
Current: 82
| Potential: 94
| Field | Value |
|---|---|
| Id | 4458266 |
| BUILDING REFERENCE NUMBER | 1236102913 |
| OSG REFERENCE NUMBER | 130188419 |
| ADDRESS1 | 8 PINEFIELD |
| ADDRESS2 | — |
| ADDRESS3 | CARRBRIDGE |
| POSTCODE | PH23 3BL |
| INSPECTION DATE | 2025-06-13 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2025-06-13 |
| ENERGY CONSUMPTION CURRENT | 157.00 |
| TOTAL FLOOR AREA | 82 |
| 3 YR ENERGY COST CURRENT | 3039.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 339.0000 |
| CURRENT ENERGY EFFICIENCY | 80 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 94 |
| POTENTIAL ENERGY RATING | A |
| ENVIRONMENT IMPACT CURRENT | 82 |
| CURRENT ENVIRONMENTAL RATING | B |
| ENVIRONMENT IMPACT POTENTIAL | 94 |
| POTENTIAL ENVIRONMENTAL RATING | A |
| CO2 EMISS CURR PER FLOOR AREA | 27.00 |
| IMPROVEMENTS | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 378; Energy Rating after improvement: A 94; Environmental Rating after improvement: A 94; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 114; Energy Rating after improvement: B 83; Environmental Rating after improvement: B 85; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALL ENERGY EFF | Very Good |
| WALL ENV EFF | Very Good |
| ROOF DESCRIPTION | Pitched, 400+ mm loft insulation |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| FLOOR DESCRIPTION | Solid, insulated (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Air source heat pump, radiators, electric |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.20 |
| CO2 EMISSIONS POTENTIAL | 1.10 |
| HEATING COST CURRENT | 1731.0000 |
| HEATING COST POTENTIAL | 1737.0000 |
| HOT WATER COST CURRENT | 1032.00 |
| HOT WATER COST POTENTIAL | 687.00 |
| LIGHTING COST CURRENT | 276.00 |
| LIGHTING COST POTENTIAL | 276.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | Description: Air source heat pump | |
| SPACE HEATING DEMAND | 5525 |
| WATER HEATING DEMAND | 2346 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | — |
| FLOOR HEIGHT | 2.41 |
| DATA ZONE | — |
| ENERGY CONSUMPTION POTENTIAL | 81.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 11 |
| LOW ENERGY FIXED LIGHT COUNT | 11 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | — |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | heat pump with radiators or underfloor heating |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2207 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | — |
| CONSTITUENCY LABEL | — |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | End-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | — |
| CREATED AT | 13/06/2025 14:16:05 |
| REPORT REFERENCE NUMBER | 0192-2327-1663-2095-0151 |
| Source file | Q2 2025.csv |
| Address display | 8 PINEFIELD , CARRBRIDGE |
| Nation | scotland |