Energy Performance Certificate
FLAT 2/2 , 53 BUDHILL AVENUE , GLASGOW, G32 0PG
Energy rating
Current: 66 D | Potential: 79 C
Environmental impact (CO₂)
Current: 65
| Potential: 83
| Field | Value |
|---|---|
| Id | 4246286 |
| BUILDING REFERENCE NUMBER | 1000985761 |
| OSG REFERENCE NUMBER | 906700225716 |
| ADDRESS1 | FLAT 2/2 |
| ADDRESS2 | 53 BUDHILL AVENUE |
| ADDRESS3 | GLASGOW |
| POSTCODE | G32 0PG |
| INSPECTION DATE | 2021-05-21 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2021-05-21 |
| ENERGY CONSUMPTION CURRENT | 284.00 |
| TOTAL FLOOR AREA | 50 |
| 3 YR ENERGY COST CURRENT | 1818.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 765.0000 |
| CURRENT ENERGY EFFICIENCY | 66 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 79 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 65 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 83 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 50.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £30; Typical Saving: 39; Energy Rating after improvement: C 78; Environmental Rating after improvement: C 80; Green Deal Eligible: N | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 34; Energy Rating after improvement: C 79; Environmental Rating after improvement: B 83; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 180; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 79; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor | Poor |
| WALL ENV EFF | Poor | Poor |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.50 |
| CO2 EMISSIONS POTENTIAL | 1.30 |
| HEATING COST CURRENT | 1293.0000 |
| HEATING COST POTENTIAL | 687.0000 |
| HOT WATER COST CURRENT | 258.00 |
| HOT WATER COST POTENTIAL | 234.00 |
| LIGHTING COST CURRENT | 267.00 |
| LIGHTING COST POTENTIAL | 132.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 5911 |
| WATER HEATING DEMAND | 1702 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -3584 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 2.75 |
| DATA ZONE | S01003305 (Shettleston North) |
| ENERGY CONSUMPTION POTENTIAL | 140.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | mid floor |
| FLAT TOP STOREY | 02 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | Glasgow City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | 6.85 |
| CONSTITUENCY | 00QSMW |
| CONSTITUENCY LABEL | Baillieston |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | End-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01010140 (Shettleston North - 04) |
| CREATED AT | 21/05/2021 16:28:18 |
| REPORT REFERENCE NUMBER | 0170-2159-6050-2829-6935 |
| Source file | Q2 2021.csv |
| Address display | FLAT 2/2 , 53 BUDHILL AVENUE , GLASGOW |
| Nation | scotland |