Energy Performance Certificate
152 PERSLEY DEN VIEW , ABERDEEN, AB21 9JN
Energy rating
Current: 84 B | Potential: 84 B
Environmental impact (CO₂)
Current: 95
| Potential: 95
| Field | Value |
|---|---|
| Id | 4410082 |
| BUILDING REFERENCE NUMBER | 1236409513 |
| OSG REFERENCE NUMBER | 9051159186 |
| ADDRESS1 | 152 PERSLEY DEN VIEW |
| ADDRESS2 | — |
| ADDRESS3 | ABERDEEN |
| POSTCODE | AB21 9JN |
| INSPECTION DATE | 2024-06-11 |
| TYPE OF ASSESSMENT | SAP, new dwelling |
| LODGEMENT DATE | 2024-06-11 |
| ENERGY CONSUMPTION CURRENT | 39.00 |
| TOTAL FLOOR AREA | 71 |
| 3 YR ENERGY COST CURRENT | 1704.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 0.0000 |
| CURRENT ENERGY EFFICIENCY | 84 |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY EFFICIENCY | 84 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 95 |
| CURRENT ENVIRONMENTAL RATING | A |
| ENVIRONMENT IMPACT POTENTIAL | 95 |
| POTENTIAL ENVIRONMENTAL RATING | A |
| CO2 EMISS CURR PER FLOOR AREA | 7.00 |
| IMPROVEMENTS | — |
| WALL DESCRIPTION | Average thermal transmittance 0.20 W/m²K |
| WALL ENERGY EFF | Very Good |
| WALL ENV EFF | Very Good |
| ROOF DESCRIPTION | Average thermal transmittance 0.14 W/m²K |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| FLOOR DESCRIPTION | (other premises below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: High performance glazing |
| WINDOWS ENERGY EFF | Very Good |
| WINDOWS ENV EFF | Very Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | Air permeability 3.9 m³/h.m² (as tested) |
| AIR TIGHTNESS ENERGY EFF | Good |
| AIR TIGHTNESS ENV EFF | Good |
| CO2 EMISSIONS CURRENT | 0.50 |
| CO2 EMISSIONS POTENTIAL | 0.00 |
| HEATING COST CURRENT | 990.0000 |
| HEATING COST POTENTIAL | 990.0000 |
| HOT WATER COST CURRENT | 405.00 |
| HOT WATER COST POTENTIAL | 405.00 |
| LIGHTING COST CURRENT | 309.00 |
| LIGHTING COST POTENTIAL | 309.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | Description: Solar photovoltaics | |
| SPACE HEATING DEMAND | 2331 |
| WATER HEATING DEMAND | 1629 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | — |
| FLOOR HEIGHT | — |
| DATA ZONE | S01000244 (Bucksburn North) |
| ENERGY CONSUMPTION POTENTIAL | 39.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 13 |
| LOW ENERGY FIXED LIGHT COUNT | 13 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | — |
| GLAZED AREA | 0 |
| NUMBER HABITABLE ROOMS | 0 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 0 |
| LOCAL AUTHORITY LABEL | Aberdeen City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | Gas: mains gas |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | — |
| ENERGY TARIFF | — |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | — |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | — |
| TENURE | unknown |
| TRANSACTION TYPE | new dwelling |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QAMA |
| CONSTITUENCY LABEL | Dyce/Bucksburn/Danestone |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | — |
| CREATED AT | 11/06/2024 15:58:18 |
| REPORT REFERENCE NUMBER | 0152-3399-1663-2094-8405 |
| Source file | Q2 2024.csv |
| Address display | 152 PERSLEY DEN VIEW , ABERDEEN |
| Nation | scotland |